Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 April 2015 to 2 September 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed according to EU, OECD and EPA test guidelines to a GLP recognised standard
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Part III: Classification Procedures, Test N.1: “Test Method for Readily Combustible Solids”, 2009.
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Parameter:
lower explosion limit
Remarks on result:
other: Not applicable
Parameter:
upper explosion limit
Remarks on result:
other: Not applicable
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
ignition distance (cm)
Remarks:
original parameter: flame extension (cm) (migrated information)
Remarks on result:
other: Not applicable
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
maximum flame height (cm)
Remarks:
original parameter: flame projection (cm) (migrated information)
Remarks on result:
other: Not applicable
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Not flammable
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.

The test item burned in contact with the flame of the gas burner emitting yellow sparks and then turned into a light yellow residue. After removal of the ignition source, no propagation of combustion of the test item was observed.

Interpretation of results:
non flammable
Remarks:
Migrated information Not highly flammable
Conclusions:
The preliminary screening test was performed for the determination of the flammability of (1,2-Dioxoethylen)bis(iminoethylen)bis[3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionat].
No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines,
performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.
Executive summary:

The purpose of this study was to determine the flammability of the test substance of (1,2-

Dioxoethylen)bis(iminoethylen)bis[3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionat] in accordance with:

European Community (EC), EC no. 440/2008, Part A: Methods for the Determination of Physico- Chemical Properties, Guideline A.10: “Flammability (Solids)”, Official Journal of the European Union no. L142, May 31, 2008.

United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to Class 2, Class 3, Class 4, Division 5.1, Class 8 and Class 9, Test N.1: “Test Method for Readily Combustible Solids”, 2009.

The results of the study showed no propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.

Description of key information

The preliminary screening test was performed for the determination of the flammability of (1,2-

Dioxoethylen)bis(iminoethylen)bis[3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionat].

No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines,

performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The purpose of this study was to determine the flammability of the test substance of (1,2-

Dioxoethylen)bis(iminoethylen)bis[3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionat] in accordance with:

European Community (EC), EC no. 440/2008, Part A: Methods for the Determination of Physico- Chemical Properties, Guideline A.10: “Flammability (Solids)”, Official Journal of the European Union no. L142, May 31, 2008.

United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to Class 2, Class 3, Class 4, Division 5.1, Class 8 and Class 9, Test N.1: “Test Method for Readily Combustible Solids”, 2009.

 

The results of the study showed no propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.

Justification for classification or non-classification

No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’. No classification is applicable.