Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 22nd, 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Principles of method if other than guideline:
Laser Light Scattering - Internal procedure SOP - STR 071 (Hydro 20000S)
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
ca. 21.214 µm
Percentile:
D10
Mean:
ca. 5.058 µm
Remarks on result:
other: after 2 minutes of ultrasonic treatment.
Percentile:
D50
Mean:
ca. 21.214 µm
Remarks on result:
other: after 2 minutes of ultrasonic treatment.
Percentile:
D90
Mean:
ca. 50.227 µm
Remarks on result:
other: after 2 minutes of ultrasonic treatment.

Specific surface area = 0.51 m2/g

Conclusions:
Mean mass diameter (MMD) = 21.214 µm.
Executive summary:

The particle size distribution of the test substance was determined by laser light diffraction. The test substance has a mean mass diameter (MMD) of 21.214 µm.

Description of key information

MMD = 21.214 µm.

Additional information

D10 = 5.058 µm

D50 = 21.214 µm

D90 = 50.227 µm