First-aid measures

IF exposed or concerned: Get medical advice/attention. Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves.

Inhalation

Skin contact

Eye contact
Ingestion

4.2. Most important symptoms and effects, both acute and delayed
4.3. Indication of any immediate medical attention and special treatment needed

If exposed to excessive levels of dusts or fumes, remove to fresh air and get medical attention if cough or other symptoms develop. If breathing is difficult, trained personnel should give oxygen.
Immediately flush skin with plenty of water. Take off contaminated clothing and wash before reuse. Get medical attention if symptoms occur.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
IF SWALLOWED: Immediately call a POISON CENTRE or doctor/physician. Do not induce vomiting without advice from poison control center.

Fire-fighting measures

General fire hazards
Extinguishing media Suitable extinguishing media
Unsuitable extinguishing media
Special hazards arising from the substance or mixture
Advice for firefighters Special protective equipment for firefighters
Special fire fighting procedures
Specific methods

This material will support combustion. Water. Foam. Dry chemical powder.
Carbon dioxide (CO2).

During fire, gases hazardous to health may be formed.



Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

Apply extinguishing media carefully to avoid creating airborne dust. Move containers from fire area if you can do so without risk.
Use standard firefighting procedures and consider the hazards of other involved materials

Accidental release measures

Personal precautions, protective equipment and emergency procedures
For non-emergency personnel





For emergency responders

Environmental precautions

Methods and material for containment and cleaning up













Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Dust deposits should not be allowed to accumulate on surfaces, as these may form an explosive mixture if they are released into the atmosphere in sufficient concentration. Use only non-sparking tools. Wear appropriate protective equipment and clothing during clean-up. Do not breathe dust.
Wear a dust mask if dust is generated above exposure limits. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Ensure adequate ventilation. Local authorities should be advised if significant spillages cannot be contained.
Keep unnecessary personnel away.
SDS.
Avoid release to the environment. Prevent further leakage or spillage if safe to do so. Avoid discharge into drains, water courses or onto the ground. Inform appropriate managerial or supervisory personnel of all environmental releases.
Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Take precautionary measures against static discharge. Use only non-sparking tools. Avoid dispersal of dust in the air (i.e., clearing dust surfaces with compressed air). The product is immiscible with water and will spread on the water surface. Stop the flow of material, if this is without risk.

Large Spills: Wet down with water and dike for later disposal. Shovel the material into waste container. If sweeping of a contaminated area is necessary use a dust suppressant agent which does not react with the product. Collect dust using a vacuum cleaner equipped with HEPA filter. Minimise dust generation and accumulation. Prevent product from entering drains. Following product recovery, flush area with water.

Handling and storage

Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Explosion-proof general and local exhaust ventilation. Minimise dust generation and accumulation. Avoid significant deposits of material, especially on horizontal surfaces, which may become airborne and form combustible dust clouds and may contribute to secondary explosions. Routine housekeeping should be instituted to ensure that dusts do not accumulate on surfaces. Dry powders can build static electricity charges when subjected to the friction of transfer and mixing operations. Provide adequate precautions, such as electrical grounding and bonding, or inert atmospheres. Ground/bond container and receiving equipment. Minimise the use of plastics when handling this material. Do not breathe
dust. Do not get this material in contact with eyes. Avoid prolonged exposure. Do not taste or swallow. When using, do not eat, drink or smoke. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Avoid release to the environment. Observe good industrial hygiene practices.
Keep away from heat, sparks and open flame. Keep containers tightly closed in a dry, cool and well-ventilated place. Store away from incompatible materials

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engineering controls





Ventilate as needed to control airborne dust. Use explosion-proof ventilation equipment if airborne dust levels are high. Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne levels below recommended exposure limits. If engineering measures are not sufficient to maintain concentrations of dust particulates below the OEL (occupational exposure limit), suitable respiratory protection must be worn.
Personal protection equipment should be chosen according to the CEN standards and in discussion with the supplier of the personal protective equipment. Follow all local regulations if personal protective equipment (PPE) is used in the workplace.
Wear appropriate chemical resistant gloves. Select suitable chemical resistant protective gloves (EN 374) with a protective index 6 (>480min permeation time). The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other.
Wear appropriate chemical resistant clothing. (EN 14605 for splashes, EN ISO 13982 for dust). When workers are facing concentrations above the exposure limit they must use appropriate
certified respirators. Where breathable aerosols/dust are formed, use suitable combination filter for gases/vapours of organic, inorganic, acid inorganic, alkaline compounds and toxic particles (eg.
EN 14387).

Wear appropriate thermal protective clothing, when necessary.

Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. For advice on suitable monitoring methods, seek guidance from a qualified environment, health and safety professional.

Stability and reactivity

The product is stable and non-reactive under normal conditions of use, storage and transport. Material is stable under normal conditions.
No dangerous reaction known under conditions of normal use.

Keep away from heat, sparks and open flame. Contact with incompatible materials. Minimise dust generation and accumulation. Avoid dispersion as a dust cloud.
Strong oxidising agents.
Irritating and/or toxic fumes and gases may be emitted upon the product's decomposition.

Disposal considerations

Dispose of in accordance with local regulations. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe manner (see: Disposal instructions).
Empty containers should be taken to an approved waste handling site for recycling or disposal. Since emptied containers may retain product residue, follow label warnings even after container is emptied.

The Waste code should be assigned in discussion between the user, the producer and the waste disposal company.



Special precautions

Collect and reclaim or dispose in sealed containers at licensed waste disposal site. Do not discharge into drains, water courses or onto the ground. Dispose in accordance with all applicable regulations.