Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

- Inhalation: Remove to fresh air and keep at rest in a position comfortable for breathing. Call a doctor if you feel unwell.

- Skin Contact: Wash with soap and water. If skin irritation occurs: Get medical advice and attention.

- Eye Contact: Rinse cautiously with water for several minutes. If eye irritation persists: Get medical advice and attention.

- Ingestion: Rinse mouth. Call a doctor if you feel unwell.

Fire-fighting measures

- Extinguishing Media

Small fires: Dry chemical, CO2 or water spray.

Large fires: Water spray, fog or regular foam.

- Unsuitable Extinguishing Media: Straight streams.

- Specific Hazards: Containers may explode when heated. Fire may produce irritating, corrosive and/or toxic gases.

- Specific Fire Fighting: Move containers from fire area if you can do it without risk. Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out.

- Protection of Fire Fighter: In fire fighting, wear respiratory protection and chemical protective clothing.

Accidental release measures

- Personal Precautions, Protective Equipment and Emergency Procedures: Wear appropriate personal protective equipment and avoid inhalation or contact with eyes and skin.

- Environmental Precautions: Pay attention not to cause the influence on the environment by discharging into rivers. Do not release into the environment.

- Decontamination/Absorption/Sweeping/Vacuuming/Neutralisation: Collect material into container for later disposal.

- Methods and Equipment for Containment and Cleaning up: Stop leak if you can do it without risk.

- Prevention Measures for Secondary Accidents: Prevent entry into waterways, sewers, basements or confined areas. Cleanse the floor surface frequently not to cause slipping.

Handling and storage

HANDLING

- Technical Measures: Provide ventilation system and use necessary personal protective equipment.

- Local and General Ventilation: Provide local and general ventilation

- Precautions for Safe Handling: Avoid breathing dust and fumes, avoid contact with eyes, avoid swallowing, wash hands thoroughly after handling and avoid contact with skin.

STORAGE

- Technical Measures: The storage facility should be provided with necessary lighting and ventilator to store and handle dangerous goods.

- Incompatible Substances or Mixtures: Strong oxidising agents.

- Keeping condition: Store away from oxidants.

- Material Used in Packaging/Containers: Packaging materials and containers are not legislated, but use sturdy and closed-type containers.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not regulated for transport
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not regulated for transport
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not regulated for transport
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not regulated for transport
Shippingopen allclose all
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Safety precautions during transportation:
- Avoid direct sunlight.
- Confirm any damage and leaking of container before transportation.
- Prevent fall, or drop to avoid getting any damage of container.
- When on loading, be careful not to collapse cargo stacks.

Exposure controls / personal protection

- Engineering Controls: Ventilation should be sufficient to control airborne levels. Facilities storing or utilising this product should be equipped with an eyewash facility and safety shower.

- Personal Protective Equipment:

Respiratory Protection: In case of insufficient ventilation, wear suitable respiratory equipment.

Hand Protection: Wear suitable gloves.

Eye Protection: Wear eye protection.

Skin and Body Protection: Wear suitable protective clothing.

- Specific Hygiene Measures: Wash hands thoroughly after handling.

Stability and reactivity

- Stability: Stable under normal conditions.

- Possibility of Hazardous Reaction: No data available

- Conditions to Avoid: No data available

- Incompatible Materials: Strong oxidizing agents.

- Hazardous Decomposition Products: Burning can produce carbon monoxide, nitrogen oxides.

* Dust Explosion Data: Lower explosion limit: 55 to 60 g/m^3. Min. ignition energy: 0.3 mJ < MIE ≤ 1 mJ, Max. pressure increase rate: 601 bar/s

Disposal considerations

- Residual Waste: Disposal should be in accordance with applicable regulations and standards by the respective local governments. Commission a waste disposal company, or a local public body who are licensed by local or regional government, to dispose of the material. When commissioning the disposal to a disposal company, notify the danger and toxicity thoroughly to the company.

- Contaminated Container and Packaging: Recycle containers after cleansing, or carry out the disposal under the related laws and regulations and the standards of the local governments. In case of disposal of empty containers, rinse the content thoroughly.