Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 February 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
GLP Study according to the EU guideline
Qualifier:
according to guideline
Guideline:
other: UN Handbook "Manual of Tests and Criteria" Rev. 7, Method 32.4 "Test methods used for determining flash point and viscosity"
Version / remarks:
2019
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Inspected on 15-/6 November 2017, signed on 15 May 2018
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Appearance yellow to red, clear liquid
Storage room temperature (20 ± 5 °C)

Key result
Flash point:
ca. 98 °C
Atm. press.:
ca. 101 325 Pa

Determination of the Flash Point


The results of the determinations are presented in the following tables.


Table 1 : Findings
































Program



Expected flash point (setting)


in °C



Flash point (found)
in °C



Mean
in °C



Notes



Search



210



100.6



 



not used for calculation (pre-test)



EN ISO 2719-B



100



97.5



98.0



difference < 2 K



EN ISO 2719-B



100



98.5



 


Evaluation and Result


The flash point is given as the mean value of the duplicate determination. The measured
flash point is therefore 98.0 ± 0.5 °C (corresponding to 371.2 ± 0.5 K).


The difference between the two values which were measured was below 2 K. For this reason,
the determination was considered valid.

Interpretation of results:
GHS criteria not met
Remarks:
EU-CLP criteria not met
Conclusions:
The flash point of the test item is 98.0 ± 0.5°C (371.2 ± 0.5 K).

The flash point of the test substance is above the classification threshold of 60 °C (CLP criteria) and 93 °C (GHS criteria). Therefore, the test substance is NOT a flammable liquid according to GHS and CLP criteria.
Executive summary:

The flash point of test item was determined under GLP according to the EU method A.9, OPPTS 830.6315 and UN Manual Test Methods 32.4.


The flash point of the test item is 98.0 ± 0.5 °C (371.2 ± 0.5 K)(mean value of two independant determinations).


The flash point of the test substance is above the classification threshold of 60 °C (CLP criteria) and 93 °C (GHS criteria). Therefore, the test substance is NOT a flammable liquid according to GHS and CLP criteria.


 

Description of key information

The flash point of the test item is 98.0 ± 0.5°C (371.2 ± 0.5 K).


The flash point of the test substance is above the classification threshold of 60 °C (CLP criteria) and 93 °C (GHS criteria). Therefore, the test substance is NOT a flammable liquid according to GHS and CLP criteria.


Note that the result obtained on this kind of substance could be largely influence by small amounts of volatile constituents.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
98 °C

Additional information

The flash point of the test substance was determined under GLP according to EU Method A.9 (Flash-Point), OPPTS 830.6315 and UN Manual Test Methods 32.4., using a non-equilibrium closed cup method. It is considered as a key study and the result is retained as key data.