EC number: 608-856-2 | CAS number: 33300-19-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
After inhalation: If breathed in, move person into fresh air. If not breathing give artificial respiration. Call a physician.
After ingestion: If swallowed, wash out mouth with water provided person is conscious. Never give anything by mouth to an unconscious person. Call a physician.
After skin contact: In case of contact, immediately wash skin with soap and copious amounts of water. Remove contaminated clothes. Call a physician.
After eye contact: Separate the eyelids with fingers and flush with copious amounts of water for 15 minutes. Call a physician.
Most important symptoms and effects, both acute and delayed
Symptoms an effects of exposure: For information on potential signs and symptoms of exposure, see Section 2-
Hazards Identification and/or Section 11-Toxicological Information.
Indication of immediate medical attention and special treatment needed
Treatment: Treat symptomatically.
Fire-fighting measures
Extinguishing media:
Water spray, carbon dioxide, dry chemical powder or appropriate foam.
Avoid high pressure media that could lead to the formation of a potential explosive mixture of dust an air.
Special risks:
Emits toxic fumes under fire conditions: carbon oxides, nitrogen oxides.
As with all dry powders it is advisable to ground mechanical equipment in contact with dry material to dissipate the potential buildup of static electricity.
Special Protective Equipment for Firefighters:
Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes.
Accidental release measures
Procedure(s) of personal precaution(s):
Use personal protective equipment. Avoid breathing dust. Ensure adequate ventilation. Evacuate personnel to safe areas.
Environmental precautions:
Prevent further leakage or spillage. Do not let product enter drains. Place waste in an appropriately labelled sealed container for disposal.
Methods for cleaning up:
Sweep up, place in a bag labelled and tightly closed for disposal according to local / national regulations.
Avoid raising dust. Ventilate area and wash spill site after material pickup is complete.
Handling and storage
Precautions for Safe Handling:
Minimize dust generation and accumulation. Do not breathe dust. Do not get in eyes, on skin or on clothing. Avoid prolonged or repeated exposure. Provide appropriate exhaust ventilation at places where dust is formed. When handling, use appropriate personal protective equipment (see Section 8).Wash thoroughly after handling and before eating or drinking. Wash contaminated clothing before reuse
Releases to the environment should be avoided. Review and implement appropriate technical and procedural waste water and waste disposal measures to prevent occupational exposure or environmental releases.
Potential points of process emissions of this to the atmosphere should be controlled with dust collectors, HEPA filtration systems or other equivalent controls.
Storage:
No special conditions are required
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control Parameters
Control exposure to the range of 10 mcg/m3 to 100 mcg/m3. Not information available.
Engineering controls:
Engineering controls should be used as the primary means to control exposures. General room ventilation is adequate unless the process generates dust, mist or fumes. Keep airborne contamination levels below the exposure limits.
Personal protective equipment:
Respiratory protection: An exposure risk assessment should be done in order to choose appropriate respiratory protection. If the applicable Occupational Limit Exposure (OEL) is exceeded, wear an appropriate respirator with a protection factor sufficient to control exposures to below the OEL. Use respirators and components tested and under appropriate government standards such as NIOSH (US) or CEN (EU).
Hand protection: Rubber gloves, according to EU Directive 89/686/EEC and the standard EN374 derived from it.
Eye protection: Chemical safety goggles, according to EN166.
Body protection: Protect skin exposed.
Stability and reactivity
Reactivity; n/a
Chemical stability: Stable under storage conditions.
Possibility of hazardous reactions
Conditions to avoid: Avoid heating.
Incompatible materials: n/a
Hazardous decomposition products: Under fire conditions: carbon oxides, nitrogen oxides.
Disposal considerations
Waste treatment methods:
Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Observe all federal, state, and local environmental regulations.
Packaging:
Contaminated packaging must be handled in the same way as the material: it must be managed by an authorized external company according to all federal, state and local regulations. Uncontaminated packaging be treated as
household waste or recyclable material. Certificate of the final treatment must be submitted by the external company.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.