Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 280-041-0 | CAS number: 82799-44-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
4.1. Description of first aid measures
General information:
Pay attention to self-protection.
In case of unwellness, call a physician. Show this safety data sheet to the physician.
After inhalation:
Remove affected person to fresh air. In case of unwellness, seek medical advice.
After skin contact:
Immediately wash with plenty of water and soap, and rinse thouroughly.If irritation persists, consult a physician.
After eye contact:
Rinse opened eye for several minutes under running water. If irritiation persists, consult an ophthalmologist.
After swallowing:
Thoroughly rinse mouth with water and let 1 - 2 glasses of water be drunken. Do not induce vomiting.
Call a physician.
If unconscious place in recovery position and call a physician immediately.
Never give anything by mouth to an unconscious person.
4.2. Most important symptoms and effects, both acute and delayed
No information available.
4.3. Indication of any immediate medical attention and special treatment needed
Treat symptomatically (decontamination, vital functions).
Fire-fighting measures
5.1. Extinguishing media
5.1.1 Suitable extinguishing media: Water spray, alcohol-resistant foam, dry powder, carbon dioxide (CO2).
Fight larger fires with water spray or alcohol-resistant foam.
Use fire extinguishing methods suitable to surrounding conditions.
5.1.2 Unsuitable extinguishing media which must not be uses for safety reasons: Strong water jet.
5.2. Special hazards arising from the substance or mixture
Substance is combustible. Risk of explosions of dust/air mixtures. On heating: increased fire hazard.
Hazardous decomposition products: Toxic gases/vapours, e.g. carbon monoxide (CO), carbon dioxide (CO2), sulphur
dioxide, smoke.
5.3. Advice for firefighters
Special protective equipment for fire fighters:
Full protective equipment. Wear self-contained breathing apparatus.
Contaminated water from fire hoses etc., must be prevented from draining into watercourses, sewers, or the ground
water. Sufficient measures must be taken to retain water used for extinguishing.
Ignition residues, contaminated water and soil must be disposed of in conformity with local regulations.
Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Wear personal protective equipment (gloves, protective clothing, goggles).
Remove all sources of ignition. Avoid dust formation. Do not breathe dust. Avoid contact with eyes, skin, and clothing.
Keep unprotected persons away.
6.2. Environmental precautions
Do not allow to enter into sewers / surface water or drains.
Do not allow to enter into soil.
6.3. Methods and material for containment and cleaning up
Dry product: mechanically take up (sweep together and shovel up) material.
Or soak up with approved explosion-proof industrial vacuum cleaner. Avoid dust formation.
Place in a suitable, correctly labelled, tightly sealed waste container for recycling or disposal.
In case of solutions:
Bunding of bigger quantities and pumping into suitable containers.
Minor quantities: soak up with inert absorbent (e.g. sand, kieselguhr).
Collect in closed and suitable containers for recycling or disposal.
Clean contaminated area thoroughly. Prevent runoff from entering drains or sewers.
6.4. Reference to other sections
Personal protective equipment: see Section 8; Disposal: see Section 13.
Handling and storage
7.1. Precautions for safe handling:
Keep container tightly closed. Keep away from sources of ignition - No smoking. (Dust may form explosive mixture with
air).
Take precautionary measures against static discharges.
Ensure good ventilation / exhaustion at the workplace.
Avoid formation of dust/vapours/aerosol.
Any deposit of dust which cannot be avoided must be regularly removed.
Do not breathe dust/vapours/aerosols.
Avoid contact with eyes, skin and clothing.
Make available sufficient washing facilities at the workplace. Provide eye shower.
In case of working with bigger quantities, provide emergency shower.
General hygienic measures:
Do not to eat, drink and smoke in work areas.
Wash hands thoroughly before breaks and after work.
Contaminated clothing should be cleaned by suction and not by blowing off or by brushing.
Separate storage of work clothes.
7.2. Conditions for safe storage, including any incompatibilities:
Store away from sources of ignition, heat and light sources, oxidising agents, and other incompatible substances (see
section 10.5.).
Protect from humid air and moisture.
Store away from pharmaceutical products, food, beverages and feedingstuff.
Keep the packing tightly closed and store in cool and dry area with good ventilation, and protected from light.
Recommended storage temperature: < 35 °C.
Storage class (TRGS 510): 11 (combustible solids).
7.3. Specific end uses(s):
Photoinitiator for UV curable printing inks and coatings (industrial and professional use).
Intermediate for organic syntheses.
Laboratory chemical.
(industrial and professional use only.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
8.1. Control parameters:
Components with occupational exposure limits requiring monitoring:
Austria (Grenzwerteverordnung 2011): No occupational exposure limit value established for CAS 82799-44-8.
Belgium: (BELGISCH STAATSBLAD — 14.03.2002 — Ed. 2 — MONITEUR BELGE): no occupational exposure limit value
established for CAS 82799-44-8.
France (Valeurs limits d'exposition professionelle aux agents chimiques en France, http://www.inrs.fr/ ):
no occupational exposure limit value established for CAS 82799-44-8.
Germany (TRGS 900, version dated 29.06.2015): no occupational exposure limit value established for CAS 82799-44-8.
General dust limit value: alveolar fraction: max. 1,25 mg/m3; inhalable fraction: 10 mg/m3.
Switzerland (SUVA 2012): no occupational exposure limit value established for CAS 82799-44-8.
United Kingdom (http://www.hse.gov.uk/coshh/): no occupational exposure limit value established for CAS 82799-44-8.
DNEL Workers: No data available.
DNEL General population: No data available.
PNEC: No data available.
8.2. Exposure controls
8.2.1. Appropriate engineering controls
Technical measures and appropriate working procedures have priority over the use of personal protective equipment.
See section 7.
8.2.2 Individual protection measures
Eye protection: Tightly sealed goggles (EN 166)
Protection of hands:
In case of long-term contact: protective gloves.
To avoid skin problems, reduce the wearing of gloves to the required minimum.
The protective gloves must comply with the specifications of EC-Directive 89/686/EEC and the corresponding norm EN
374 (in connection with DIN EN 420 and DIN EN 388).
The glove material has to be impermeable and resistant to the product/ the substance.
Due to missing tests no recommendation to the glove material can be given for the product / the chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation.
Glove material:
The selection of suitable gloves does not only depend on the material, but also on further quality characteristics and
varies from manufacturer to manufacturer.
Penetration time of glove material:
The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Body protection: protective clothing.
Protective clothing needs to be selected specifically for the workplace, depending on the concentrations and
quantities of the hazardous substances handled.
Respiratory protection:
Not necessary if exhaust ventilation at the workplace is working well.
Respiratory protection:is needed if technical suction / ventilation measures are not possible or not sufficient, and if
treshold limits are exceeded.
In case of short-term or low exposure: use filtering device. Respirator type: filter P1 or P2.
In case of long-term exposure or higher levels of exposure: wear self-contained breathing apparatus.
Observe the wear time limits according to GefStoffV in combination with the rules for using respiratory protection
apparatus (BGR 190).
The employer shall ensure that maintenance, cleaning and inspection of respiratory protective equipment is carried out
in accordance with the equipment manufacturer's instructions.
Attention: respiratory protection devices with air filters do not protect against oxygen deficiencies at the workplace. If
the concentration of oxygen in the workplace is less than 17%, wear self-contained breathing apparatus.
8.2.3 Environmental exposure controls
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements
of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the
process equipment will be necessary to reduce emissions to acceptable levels.
Stability and reactivity
10.1. Reactivity
No data available.
10.2. Chemical stability
Heat sensitive; light sensitive.
Stable under recommended conditions of storage and absence of incompatible materials / conditions to avoid.
10.3. Possibility of hazardous reactions
Risk of explosions of dust/air mixtures.
Danger of violent reactions / explosions with strong oxidizing agents.
10.4. Conditions to avoid
Static discharges, ignition sources, light, heat.
Do not overheat in order to avoid thermal decomposition.
Avoid dust formation. Avoid formation of aerosols.
10.5. Incompatible materials
Strong oxidising agents, strong reducing agents, strong acids, strongly alkaline substances.
10.6. Hazardous decomposition products
No data available.
Hazardous combustion products: see Section 5.
Disposal considerations
13.1. Waste treatment methods:
Disposal according to local regulations. This material may only be disposed of by a licensed waste disposal company.
Disposal: Incineration at a licensed installation, observing national and local legislation.
Do not dispose via sewage. Do not allow product to reach sewage system. Do not allow to enter into soil/subsoil.
Uncleaned packaging:
Recommendation: Disposal must be made according to official regulations.
European Waste Catalogue
The allocation of waste identity numbers/waste descriptions must be carried out according to the EWC,
specific to the industry and process.
Community provisions relating to waste:
1. Directive 2008/98/EC of the European Parliament and of the Council of 19 November 2008 on waste and repealing
certain Directives; Official Journal of the European Union, L 312 of 22.11.2008, page 3 - 30.
2. Directive 2006/12/EC of the European Parliament and of the Council of 5 April 2006 on waste,
Official Journal of the European Union, L 114 of 27.04.2006, page 9 – 21.
3. Regulation (EC) No 1013/2006 of the European Parliament and of the Council of 14 June 2006 on shipments of waste;
Official Journal of the European Union L 190, 12.7.2006, p. 1–98
4. Local official regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.