Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 04/07/08 to 07/10/08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: In compliance with Commission Regulation (EC) N° 440/2008 A21 method (2008)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Isosorbide Diesters
EC Number:
700-073-5
Cas Number:
1215036-04-6
Molecular formula:
As it is an UVCB, we can not provide the exact molecular formula.
IUPAC Name:
Isosorbide Diesters
Details on test material:
- Name of test material (as cited in study report): LAB 3822


- Physical state: Liquid
- Impurities (identity and concentrations): Isosorbide monoesters (11%) ; Residual organic acids (0.5%) ; Water (0.1%)

- Lot/batch No.: FAL 07/25
- Expiration date of the lot/batch: 2009

- Storage condition of test material: In darkness at room temperature

Study design

Contact with:
powdered cellulose

Results and discussion

Test results (Oxidising liquids)
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
mean pressure rise time
Result:
14 411 ms
Remarks on result:
other: The mean pressure rise time obtained with the mixture test item / cellulose was upper than the mean pressure rise time obtained with the mixture reference item.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
The test item was not considered to have oxidizing properties in our experimental conditions.