The water solubility of Setafix X11342 was determined to be 0.0000088g/L (see NOTOX Project 330918: determination of water solubility of Setafix X 11342). Based on this water solubility, the hydrolysis test has to be performed at a maximum concentration of 0.0000044g/L..

In the hydrolysis test, concentrations have to be measured accurately in order to draw reliable conclusions on hydrolysis rate. At concentrations <0.0000044g/L, the analytical method used during NOTOX project 330918 is not sufficiently accurate. Development of a sufficiently accurate method is expected not possible.