Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
non GLP documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Version / remarks:
EU-Verordnung 440/2008 Verfahren A.5. Oberflächenspannung mittels OECD-Ringmethode bei 25°C.
Deviations:
no
GLP compliance:
no
Remarks:
non GLP documentation but relevant data supplied
Other quality assurance:
other:
Remarks:
educational and professional experience of experimentator
Type of method:
ring method

Test material

Constituent 1
Test material form:
liquid: viscous
Details on test material:
- State of aggregation: contains polymer which is not soluble after dessication
- Particle size distribution: not appropriate (liquid)
- Mass median aerodynamic diameter (MMAD): not appropriate
- Geometric standard deviation (GSD): not appropriate
- Shape of particles: not appropriate
- Surface area of particles: not appropriate
- Crystal structure: not appropriate
- Coating: not appropriate
- Surface properties: surface tension see appropriate section of IUCLID
- Density: see appropriate section of IUCLID
- Moisture content: see above
- Residual solvent: see above
- Activation: not appropriate
- Stabilisation: not required as long as treated properly and instructions of manufacturer are followed
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: The test material is representative of the registered substance
- Expiration date of the lot/batch: not relevant
- Purity test date: not relevant

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature in the dark
- Stability under test conditions: stable
- Solubility and stability of the test substance in the solvent/vehicle: soluble

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: none
- Preliminary purification step (if any): none

Results and discussion

Surface tension
Key result
Surface tension:
ca. 41.9 mN/m
Temp.:
25 °C
Conc.:
100 vol%
Remarks on result:
other: aqueous solution
Remarks:
sales product

Applicant's summary and conclusion

Conclusions:
Surface tension of sales product ca. 47.4 +/- 0.3 mN/m
Executive summary:

The surface tension of the sales product, measured according to EU Method A.5 (Surface Tension), was ca. 47.4 +/- 0.3 mN/m