Description of first aid measures

Eye contact: Remove contact lenses, irrigate copiously with clean, fresh water, holding the eyelids apart for at least 10 minutes and seek immediate medical advice.

Inhalation: Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Skin contact:

Remove contaminated clothing and shoes. Wash skin thoroughly with soap and
water or use recognised skin cleanser. Do NOT use solvents or thinners.

Ingestion: If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.

Protection of first-aiders: No action shall be taken involving any personal risk or without suitable training. If it is suspected that fumes are still present, the rescuer shouldwear an appropriate mask or self-contained breathing apparatus. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation.

Most important symptoms and effects, both acute and delayed

Potential acute health effects
Eye contact: No known significant effects or critical hazards.
Inhalation: Can cause central nervous system (CNS) depression. May cause drowsiness or dizziness. May cause respiratory irritation.
Skin contact: Defatting to the skin. May cause skin dryness and irritation.
Ingestion: Can cause central nervous system (CNS) depression.

Over-exposure signs/symptoms

Eye contact: No specific data.

Inhalation Adverse symptoms may include the following:
respiratory tract irritation
coughing
nausea or vomiting
headache
drowsiness/fatigue
dizziness/vertigo
unconsciousness

Skin contact:: Adverse symptoms may include the following:
irritation
dryness
cracking

Ingestion: No specific data

Indication of any immediate medical attention and special treatment needed:
Notes to physician: Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Specific treatments: No specific treatment.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media: Use dry chemical, CO2, water spray (fog) or foam.
Unsuitable extinguishing media: Do not use pressurised water jet.

Special hazards arising from the substance

Hazards from the substance or mixture: Flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. This material may cause long lasting effects to aquatic life. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.

Hazardous combustion products: No specific data.

Advice for firefighters

Special precautions for firefighters: Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Special protective equipment for fire-fighters: Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

Accidental release measures

No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from
entering. Do not touch or walk through spilt material. Shut off all ignition sources.
No flares, smoking or flames in hazard area. Avoid breathing vapour or mist.
Provide adequate ventilation. Wear appropriate respirator when ventilation is
inadequate. Put on appropriate personal protective equipment.

If specialised clothing is required to deal with the spillage, take note of any
information in Exposure controls/personal protection on suitable and unsuitable materials. See also the
information in "For non-emergency personnel".

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air). Water polluting material. May be harmful
to the environment if released in large quantities. Collect spillage.

Small Spill: Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Dilute with water and mop up if water-soluble.
Alternatively, or if water-insoluble, absorb with an inert dry material and place in an
appropriate waste disposal container. Dispose of via a licensed waste disposal
contractor.

Large Spill: Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Approach the release from upwind. Prevent entry into
sewers, water courses, basements or confined areas. Wash spillages into an
effluent treatment plant or proceed as follows. Contain and collect spillage with noncombustible,
absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
and place in container for disposal according to local regulations. Dispose of via a
licensed waste disposal contractor. Contaminated absorbent material may pose the
same hazard as the spilt product.

Handling and storage

Put on appropriate personal protective equipment (see Section 8). Eating, drinking
and smoking should be prohibited in areas where this material is handled, stored and
processed. Workers should wash hands and face before eating, drinking and
smoking. Remove contaminated clothing and protective equipment before entering
eating areas. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid
breathing vapour or mist. Avoid release to the environment. Refer to special
instructions/safety data sheet. Use only with adequate ventilation. Wear appropriate
respirator when ventilation is inadequate. Do not enter storage areas and confined
spaces unless adequately ventilated. Keep in the original container or an approved
alternative made from a compatible material, kept tightly closed when not in use.
Store and use away from heat, sparks, open flame or any other ignition source. Use
explosion-proof electrical (ventilating, lighting and material handling) equipment. Use
non-sparking tools. Take precautionary measures against electrostatic discharges.
To avoid fire or explosion, dissipate static electricity during transfer by earthing and
bonding containers and equipment before transferring material. Empty containers
retain product residue and can be hazardous. Do not reuse container.
Eating, drinking and smoking should be prohibited in areas where this material is
handled, stored and processed. Workers should wash hands and face before eating,
drinking and smoking. Remove contaminated clothing and protective equipment
before entering eating areas.

Do not store above the following temperature: 50°C (122°F). Store in accordance
with local regulations. Store in a segregated and approved area. Store in original
container protected from direct sunlight in a dry, cool and well-ventilated area, away
from incompatible materials and food and drink. Store locked up.
Eliminate all ignition sources. Separate from oxidizing materials. Keep container
tightly closed and sealed until ready for use. Containers that have been opened must
be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled
containers. Use appropriate containment to avoid environmental contamination.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
1866
Shipping information
Proper shipping name and description:
RESIN SOLUTION
Chemical name:
2,3-Epoxypropyl neodecanoate, oligomeric reaction products with cyclohexane-1,2-dicarboxylic anhydride and propylidenetrimethanol
Language:
English
Special provisions / remarks
Remarks:
This class 3 viscous liquid that is also environmentally hazardous is not subject to regulation in packagings up to 5 L

Inland waterway transport (UN RTDG/ADN(R))

UN number:
1866
Shipping information
Proper shipping name and description:
RESIN SOLUTION
Chemical name:
2,3-Epoxypropyl neodecanoate, oligomeric reaction products with cyclohexane-1,2-dicarboxylic anhydride and propylidenetrimethanol
Language:
English
Special provisions / remarks
Remarks:
This class 3 viscous liquid that is also environmentally hazardous is not subject to regulation in packagings up to 5 L

Marine transport (UN RTDG/IMDG)

UN number:
1866
Shipping information
Proper shipping name and description:
RESIN SOLUTION
Chemical name:
2,3-Epoxypropyl neodecanoate, oligomeric reaction products with cyclohexane-1,2-dicarboxylic anhydride and propylidenetrimethanol
Special provisions / remarks
Remarks:
This class 3 viscous liquid that is also environmentally hazardous is not subject to regulation in packagings up to 5 L

Air transport (UN RTDG/ICAO/IATA)

UN number:
1866
Shipping information
Proper shipping name and description:
RESIN SOLUTION
Chemical name:
2,3-Epoxypropyl neodecanoate, oligomeric reaction products with cyclohexane-1,2-dicarboxylic anhydride and propylidenetrimethanol
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
This class 3 viscous liquid that is also environmentally hazardous is not subject to regulation in packagings up to 5 L

Exposure controls / personal protection

No exposure limit value known.
Recommended monitoring procedures: If this product contains ingredients with exposure limits, personal, workplace atmosphere or biological monitoring may be required to determine the effectiveness of the ventilation or other control measures and/or the necessity to use respiratory protective equipment. Reference should be made to monitoring standards, such as the following: European Standard EN 689 (Workplace atmospheres - Guidance for the assessment of exposure by inhalation to chemical agents for comparison with limit values and measurement strategy) European Standard EN 14042 (Workplace atmospheres - Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents) European Standard EN 482 (Workplace atmospheres - General requirements for the performance of procedures for the measurement of chemical agents) Reference to national guidance documents for methods for the determination of hazardous substances will also be required.

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne
contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location. Wear safety glasses with side shields, according to EN 166.

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Nitrile rubber gloves should be worn for repeated handling Considering the parameters specified by the glove manufacturer,
check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be
different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time greater than 480 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended.

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Wear a respirator conforming to EN140. Filter type: organic vapour (Type A) and particulate filter P3




Stability and reactivity

No specific test data related to reactivity are available for this product or its ingredients. The product is stable. Under normal conditions of storage and use, hazardous reactions will not occur. When exposed to high temperatures may produce hazardous decomposition products.

Keep away from the following materials to prevent strong exothermic reactions: oxidising agents, strong alkalis, strong acids. Under normal conditions of storage and use, hazardous decomposition products should not be produced.

Disposal considerations

Hazardous waste:
The generation of waste should be avoided or minimised wherever possible. Disposal of this product, solutions and any by-products should at all times comply
with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. The generation of waste should be avoided or minimised wherever possible. Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible.
This material and its container must be disposed of in a safe way. Care should be taken when handling emptied containers that have not been cleaned or rinsed out. Empty containers or liners may retain some product residues. Vapour from product residues may create a highly flammable or explosive atmosphere inside the container. Do not cut, weld or grind used containers unless they have been cleaned thoroughly internally. Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.