Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14-Jul to 07-Oct-2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
yes (incl. QA statement)
Remarks:
Gute Laborpraxis/Good Laboratory Practice GLP-Bescheiningung/Statement of GLP Compliance (gemäß/according to § 19b Abs. 1 Chemikaliengesetz)
Type of method:
closed cup
Flash point:
95 °C
Atm. press.:
1 013 hPa

Results

 

Flash point at atmospheric pressure [°C]

Flash point corrected to a pressure of 1013 hPa [°C]

Preliminary test

93.0

93.0

First run

95.0

95.0

Second run

95.0

95.0

Mean value

 

95.0

 

The flash point of the test item was determined according to EU test method A.9 [Council Regulation (EC) No 440/2008, Official Journal L 142/1 2008] with the Pensky-Martens method (closed cup).

Flash point: 95.0 °C (1013 hPa)

Conclusions:
A flash point value of 95°C at 1013 hPa was determined in a reliable study conducted according to an appropriate test protocol, and in compliance with GLP.

Description of key information

95°C at 1013 hPa (EU Method A.9, Pensky Martens closed cup)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
95 °C

Additional information