Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(methylamino)-4-[(3-methylphenyl)amino]anthraquinone
EC Number:
229-059-2
EC Name:
1-(methylamino)-4-[(3-methylphenyl)amino]anthraquinone
Cas Number:
6408-50-0
Molecular formula:
C22H18N2O2
IUPAC Name:
1-(methylamino)-4-[(3-methylphenyl)amino]-9,10-dihydroanthracene-9,10-dione
Test material form:
solid: particulate/powder
Details on test material:
Identification: 1-(methylamino)-4-[(3-methylphenyl)amino] anthraquinone
Physical state/Appearance: dark red powder
Batch: 702W01
Purity: 99.4%
Expiry Date: 08 February 2020
Storage Conditions: room temperature in the dark
Intended use/Application: industrial chemical

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

Preliminary Screening

The pilemelted and began to boil butfailed to ignite during the 2 minutes that the Bunsen flame was applied.

The result of the preliminary screening test obviated the need to perform the main test

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.