Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
migrated information: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Read-across was used. Hypothesis for the analogue approach: see files attached under section 13 assessment reports Read Across Justification. Test for source substance to relative density was performed according to EU method A.3 and compliant with GLP.

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1996

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
yes
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Density
Type:
relative density
Density:
0.95 other: (corresponds to D4(20))
Temp.:
23 °C

Applicant's summary and conclusion

Conclusions:
The relative density of test substance was determined to be 0.95 (corresponds to D4(20)) at 23°C. The test substance (source substance) bis(hydrogenated tallow C16-C18-alkyl)hydroxylamine is a structurally very similar substance to target substance hydroxylamines, di-C16-18 (even numbered) alkyl. It can be reasonably assumed that target substance has the similar relative density.