Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures:
Pay attention to self-protection.
Remove victims from hazardous area.
Immediately remove soiled or soaked clothing and remove it to a safe distance.
Keep victim warm, in a stabilizedposition and covered.
Do not leave victims unattended.
If the casualty is unconscious: Place the victim in the recovery position.

Inhalation:
Inhalation is possible if aerosols, mists, dusts, or smoke form.
Move victims into fresh air.
With labored breathing: Provide with oxygen. Consult a doctor.
If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact:
Wash off affected area immediately with plenty of water for at least 15 minutes.
If symptoms persist, consult a physician for treatment.

Eye contact:
With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.
In case of persistent discomfort: Consult an ophthalmologist.

Ingestion:
Rinse mouth.
Immediately give large quantities of water to drink.
Obtain medical attention.

Most important symptoms and effects, both acute and delayed:
Symptoms:
None known.
Hazards:
Other dangerous properties can not be excluded.

Indication of any immediate medical attention and special treatment needed:
This substance does not have any noteworthy noxious potential.
Damage to health is thus not expected.

Fire-fighting measures

Extinguishing media:
Suitable extinguishing media: All extinguishing substances suitable.
Unsuitable extinguishing media: Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:
May be released in case of fire: carbon monoxide, carbon dioxide, organic products of decomposition and nitric oxides.

Advice for firefighters:
Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.
Water used to extinguish fire should not enter drainage systems, soil or stretches of water.
In case of fire, remove the endangered containers and bring to a safe place, if this can be done safely.
Use water spray to cool unopened containers.
Fire residues should be disposed of in accordance with the regulations.
Pay attention to self-protection.
Keep out unprotected persons.
In case of fire: full protective suit and wear a self contained respiratory apparatus.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Keep unauthorized persons away.
Avoid dust formation.

Environmental precautions:
Observe regulations on prevention of water pollution (check, dam up, cover up).
Do not allow entrance in sewage water, soil, stretches of water, drainage systems, surface water.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:
Pick up mechanically and collect in a suitable container.
Avoid formation of dust.
To absorb spilled substance an approved industrial vacuum cleaner is recommended.
If necessary, the spilled substance should be moistened.
Clean contaminated surface thoroughly.
Pack and label wastes like the pure substance.
Do not detach label from the delivery containers prior to disposal.
Disposal according to local authority regulations.

Handling and storage

Precautions for safe handling:
Avoid residues of the product on the containers.

Conditions for safe storage, including any incompatibilities:
Storage:
Store in the original receptacle, keeping this tightly sealed, under cool and dry conditions.

Further information:
In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.

German storage class:
13 - Non Combustible Solids.

Transport information

Land transport (UN RTDG/ADR/RID)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Inland waterway transport (UN RTDG/ADN(R))

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters:
DNEL/DMEL values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

PNEC values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

Exposure controls:
Personal protective equipment:
Respiratory protection:
in case of occurrence of dusts:
Use respiration protection equipment with appropriate filters (filter type P1) or self-contained breathing apparatus.
Note time limit for wearing respiratory protective equipment.

Hand protection:
Applies to handling for brief periods or of small amounts:
Glove material Nitrile, for example, Dermatril 740, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness: 0.11 mm
Method: DIN EN 374
Applies to handling for longer periods or of large amounts:
Glove material Nitrile/Chloroprene, for example, Nitopren 717, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness: 0.65 mm
Method: DIN EN 374
Selection of protective gloves to meet the requirements of specific workplaces.
Suitability for specific workplaces should be clarified with protective glove manufacturers.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Remember that the use time per day of a chemical protection glove may be much shorter than the permeation time determined according to EN 374due to the many different influential factors involved (e.g. temperature).

Eye protection:
Safety glasses with side-shields conforming to EN166.

Skin and body protection:
Select materials and equipment for physical protection depending on the concentration and volume of hazardous substances and the workplace
involved.

Hygiene measures:
Avoid contact with eyes and clothing.
Wash contact areas after handling.
Take off clothing and shoes contaminated with product.
Clean before reuse.
Do not eat, drink, smoke, or sniff while at work.
Wash your hands and/or face before breaks and before termination of work.

Protective measures:
The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).
Handle in accordance with good industrial hygiene and safety practice.

Stability and reactivity

Reactivity:
No further information available.

Chemical stability:
No further information available.

Possibility of hazardous reactions:
No further information available.

Conditions to avoid:
No further information available.

Incompatible materials:
No further information available.

Hazardous decomposition products:
No further information available.

Disposal considerations

Waste treatment methods:
Product:
Disposal according to local authority regulations.
Pack and label wastes like the pure substance.
Do not detach label from the delivery containers prior to disposal.

Uncleaned packaging:
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.

Waste Key Number:
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.