Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 - 03 December 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study (with certificate) OECD and EC guidelines
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Details on properties of test surrogate or analogue material (migrated information):
PHYSICO-CHEMICAL PROPERTIES
- Melting point: less than -25°C
- Boiling point: 240°C
- Vapour pressure: 34 Pa at 25°C
- Water solubility (under test conditions): greater than 1000 g/l of water
- log Pow: 0.73
- pKa: 10.2
Analytical monitoring:
no
Vehicle:
yes
Details on test solutions:
TEST SYSTEM
- Test vessel: no data
- Aeration: no data
- Renewal rate of test solution (frequency/flow rate): no
- No. of organisms per vessel: no data
- No. of vessels per concentration (replicates):1 x 10, 30, 100, 300mg/L. 3x 1000 mg/L
- No. of vessels per control (replicates):2
- No. of vessels per positive control (replicates):1 x 3, 10, 32mg/L
- Biomass loading rate: no data

TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: reverse osmosis
no other data

OTHER TEST CONDITIONS
- Adjustment of pH: yes, using 11.7M HCl to adjust pH from ~11 to ~7.
- Photoperiod: no data
- Light intensity: no data

TEST CONCENTRATIONS
- Spacing factor for test concentrations: 3-3.2
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Method of cultivation:
A sample of activated sludge was obtained the day before the start of the test from a sewagr treatment works, which treats predominantly domestic waste. In the laboratory, the sample was maintained under aerobic conditions until required. The concentration of suspended solids in a homogenised sample was determined on the day of collection and immediately before the start of the test.

- Preparation of inoculum for exposure:
On the day of collection, an aliquot (10 mL) of the activated sludge was filtered through a dried and preweighed Whatman GF/C filter paper, which was then dried again at approximately 105°C for at least one hour, then allowed to cool in a desiccator before being reweighed. The mixed liquor suspended solids (MLSS) content of the activated sludge was then calculated. Synthetic sewage (50 mL/L) was added to the stock of activated sludge and this was aerated overnight.

- Pretreatment:
On the day of the test, the MLSS content of the sludge was determined (in triplicate) and adjusted to 4 g/L by the addition of tap water. The pH and temperature of the sludge were also measured. Aliquots (200 mL) were then added to each mixture to give a final MLSS concentration of 1.6g/L.

- Initial biomass concentration:1.6 g/L
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Post exposure observation period:
Following the exposure period, a well-mixed sample of each mixture was transferred to a biochemical oxygen demand (BOD) bottle (nominal capacity, 270 mL).
The rate of oxygen consumption was measured, over a period of approximately 10 minutes or until the dissolved oxygen concentration fell below ca. 2 mgO2/L using a Yellow Springs Instrument (YSI) dissolved oxygen meter, with temperature probe and self stirring bottle probe connected to a chart recorder.
The pH and temperature of the samples were measured at the start and end of the test.
Hardness:
no data
Test temperature:
19.6 to 19.8 °C
pH:
7.3 to 8.1.
Dissolved oxygen:
5.5 to 9.1 mgO2/L
Salinity:
freshwater
Nominal and measured concentrations:
Nominal: 0, 10, 30, 100, 300, 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Aeration: The prepared mixtures were aerated for three hours in a thermostatically-controlled water bath, using a glass aerator connected to a laboratory supply of oil-free compressed air (one litre/minute).
- Renewal rate of test solution (frequency/flow rate): no
- No. of vessels per concentration (replicates):1 x 10, 30, 100, 300mg/L. 3x 1000 mg/L
- No. of vessels per control (replicates):2
- No. of vessels per positive control (replicates):1 x 3, 10, 32mg/L

TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: reverse osmosis
no other data

OTHER TEST CONDITIONS
- Adjustment of pH: yes, using 11.7M HCl to adjust pH from ~11 to ~7

Reference substance (positive control):
yes
Remarks:
3,5-Dichlorophenol (DCP) 99%
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition
Details on results:
- Any observations (e.g. precipitation) that might cause a difference between measured and nominal values: no
- Effect concentrations exceeding solubility of substance in test medium: no

No biologically significant inhibition was observed in mixtures containing the test substance at 10, 30 and 100 mg/L.
Respiration rates were decreased by 27% at 300 mg/L and 27% to 52% (mean 37%) at 1000 mg/L.
Although the level of inhibition at 300 and 1000 mg/L was greater than that considered biologically significant (15%), it was not concentration related.
Therefore increasing the dose levels above 1000 mg/L would not give proportionally higher levels of inhibition.
Consequently no further testing was carried out and the results of this study are reported. The three-hour EC50 for 1,3-Bis(aminomethyl)cyclohexane could not be accurately calculated but was considered >1000 mg/L, the highest concentration tested. From these data, it was not possible to obtain an accurate three-hour EC20 or EC80.
Results with reference substance (positive control):
- Results with reference substance valid? yes

Sludge respiration rates were progressively reduced in the presence of increasing concentrations of 3,5-DCP. The three-hour 50% effect concentration (EC50) for 3,5-DCP was calculated to be 6.0 mg/L (95% confidence limits, 2.4 to 11.4 mg/L).

The specific respiration rates of the control culture established at the end of the test (Control 2, 17.6 mgO2/g/h) was 108% of the rate established at the start (Control 1, 16.3 mgO2/g/h).

These results show that the test was valid and that the sample of activated sludge employed was sensitive to inhibition.

Table 1: Dissolved oxygen concentrations, measurement times, respiration rates and percentage inhibition

 Test mixture   Initial DO concentration in the culture (mgO2/L)   Initial measured DO concentration (mgO2/L) (DO(1))   Final measured DO concentration (mgO2/L) (DO(2))   Measurement time (minutes) (t)   Specific respiration rate (SRR mgO2/g/h)   % inhibition 
 Control (1)  7.2   6.5   2.5   9.2   16.3   - 
 1,3-Bis(aminomethyl) cyclohexane (mg/L)            
 10   6.6   5.5   2.0   7.9   16.6   2 
 30   6.7   6.0   2.5   8.2   16.0   6 
 100   7.0   6.0   3.0   7.2   15.6   8 
 300   6.2   5.5   3.0   7.6   12.3   27 
 1000    8.2   7.3   5.5   8.3   8.1   52 
 1000    8.4   7.5   5.0   7.6   12.3   27 
 1000   7.9   7.0   4.5   8.0   11.7   31 
3,5-DCP (mg/L)              
 3   8.3   7.4   5.5   6.4   11.1   34 
 10   9.1   7.9   6.5   7.8   6.7   60 
 32   9.3   9.1   8.5   7.8   2.9   83 
 Control (2)   8.6   6.5   2.5   8.5   17.6   - 

Table 2: Temperature and pH measurements

 Test mixture   Temperature (°C)  pH   
Initial Final Initial Final
 Control (1)  19.6   19.7   7.4   8.0 
 1,3-Bis(aminomethyl) cyclohexane (mg/L)          
 10   19.7   19.8   7.4   7.9 
 30   19.7   19.8   7.4   7.9 
 100   19.8   19.8   7.5   7.9 
 300   19.8   19.7   7.4   8.0 
 1000    19.7   19.7   7.6   8.0 
 1000    19.8   19.7   7.6   8.1 
1000   19.7   19.7   7.6   8.0 
3,5-DCP (mg/L)          
 3   19.8   19.7   7.4   8.1 
 10   19.8   19.7   7.3   8.0 
 32   19.8   19.7   7.3   8.0 
 Control (2)   19.8   19.7   7.3   8.0 
Validity criteria fulfilled:
yes
Conclusions:
The three-hour EC50 for 1,3-Bis(aminomethyl)cyclohexane was >1000 mg/L, the highest concentration tested.
Executive summary:

Concentration-related inhibition of respiration rates were not observed at any of the 1,3-Bis(aminomethyl)cyclohexane concentrations. Respiration rates were decreased by 27% at 300 mg/L and 27% to 52% (mean 37%) at 1000 mg/L. The three-hour EC50 for 1,3-Bis(aminomethyl)cyclohexane could not be accurately calculated but was considered >1000 mg/L, the highest concentration tested. The three-hour EC50 for 3,5-DCP (6.0 mg/L) fulfilled the validity criterion relating to sensitivity to inhibition (acceptable EC50 range 5 to 30 mg/L). The validity criterion relating to the respiration rates in the control (variation not greater than 15%) was also satisfied.

Description of key information

The three-hour EC50 for 1,3-Bis(aminomethyl)cyclohexane was >1000 mg/L, the highest concentration tested.

Key value for chemical safety assessment

EC50 for microorganisms:
1 000 mg/L

Additional information

Concentration-related inhibition of respiration rates were not observed at any of the 1,3-Bis(aminomethyl)cyclohexane concentrations. Respiration rates were decreased by 27% at 300 mg/L and 27% to 52% (mean 37%) at 1000 mg/L. The three-hour EC50 for 1,3-Bis(aminomethyl)cyclohexane could not be accurately calculated but was considered >1000 mg/L, the highest concentration tested. The three-hour EC50 for 3,5-DCP (6.0 mg/L) fulfilled the validity criterion relating to sensitivity to inhibition (acceptable EC50 range 5 to 30 mg/L). The validity criterion relating to the respiration rates in the control (variation not greater than 15%) was also satisfied.