Registration Dossier

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was performed according to the recommended guidelines and GLP. There were minor deviations from the protocol which did not adversely affect the study integrity.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
yes
Remarks:
There were minor deviations from the protocol which did not adversely affect the study integrity.
Qualifier:
according to
Guideline:
other: DIN 51794: determining the ignition temperature of petroleum products, May 2003
Qualifier:
according to
Guideline:
other: IEC standard 79-4: Electrical apparatus for explosive gas atmospheres, part 4, method of test for ignition temperature.
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
445 °C
Atm. press.:
>= 998.2 - <= 1 005 hPa
Remarks on result:
other:

Applicant's summary and conclusion

Conclusions:
The test substance is auto-ignitable with an auto-ignition temperature of 445°C at 998.2 – 1005.0 hPa.