Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Surface tension

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-04-19 to 2010-08-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
ring method
Specific details on test material used for the study:
- Trade name: Purasolv EL
- Batch number: 0909001195
- Appearance: Clear colourless liquid
- Purity: 99.83 % w/w
- Storage: at room temperature, in the dark under nitrogen
- Expiry date: 2010-09-14
Key result
Surface tension:
70.5 mN/m
Temp.:
20 °C
Conc.:
1 g/L

Table 1. Surface tension of PURASOLV®EL (ethyl-S-lactate)

Measurement

Time passed [minutes]

Surface tension [mN/m]

individual

mean

Mean multiplied by Φband Harkins-Jordan corrected value

1

20

70.2

70.2

70.5

2

21

70.3

3

22

70.1

4

23

70.1

5

24

70.3

 

Conclusions:
The surface tension of a test solution at a ethyl (S)-lactate concentration of 1 g/L in water at 20 °C was 70.5 mN/m. The test substance is considered not to be surface active.
Executive summary:

The OECD harmonized ring method was used for determining the surface tension of PURASOLV®EL (ethyl-(S)-lactate). The surface tension of a test solution at a ethyl-(S)-lactate concentration of 1 g/L in water at 20 °C was 70.5 mN/m. The test substance is considered not to be surface active.

Description of key information

The OECD harmonized ring method was used for the determination of the surface tension of PURASOLV®EL (Ethyl (S)-lactate). The surface tension of a test solution at a Ethyl (S)-lactate concentration of 1 g/L in water at 20 °C was 70.5 mN/m. The test substance is therefore considered as not surface active.

Key value for chemical safety assessment

Surface tension:
70.5
in mN/m at 20°C and concentration in mg/L:
1 000

Additional information