Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
migrated information: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report Date:
2006

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): 1-Aminotetralin
Analytical purity: 98 % (by GC in area%)

Results and discussion

Flash point
Flash point:
112 °C
Atm. press.:
1 013.25 hPa

Applicant's summary and conclusion