Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: According to the German national standard test procedures, basic data given.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1988
Report date:
1988

Materials and methods

Principles of method if other than guideline:
Oxygen consumption test according to ROBRA which is comparable to the German National Standard, DIN 38412 Part 27 (draft), 1992.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
3,7,11,15-tetramethylhexadec-1-en-3-ol
EC Number:
208-008-8
EC Name:
3,7,11,15-tetramethylhexadec-1-en-3-ol
Cas Number:
505-32-8
Molecular formula:
C20H40O
IUPAC Name:
3,7,11,15-tetramethylhexadec-1-en-3-ol
Details on test material:
- Name of test material (as cited in study report): 3,7,11,15-Tetramethyl-1-hexadecen-3-ol (Isophytol)

Purity: no data
Water solubility: insoluble

Sampling and analysis

Analytical monitoring:
no

Test solutions

Vehicle:
yes
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: The stock solution of the test substance (nominal 10,000 mg/l) was prepared using 100 mg/l Tween 80 as an emulsifier.

Test organisms

Test organisms (species):
Pseudomonas putida

Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
30 min

Test conditions

Nominal and measured concentrations:
Nominal test concentrations: control, 50, 100 and 1000 mg/l.

Results and discussion

Effect concentrationsopen allclose all
Duration:
30 min
Dose descriptor:
EC10
Effect conc.:
> 10 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
30 min
Dose descriptor:
EC50
Effect conc.:
> 10 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
30 min
Dose descriptor:
other: EC90
Effect conc.:
> 10 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate

Applicant's summary and conclusion