Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Vapour pressure was determined at three different temperatures according to method A.4 EC 440/2008 (static method). 

Key value for chemical safety assessment

Vapour pressure:
0.002 kPa
at the temperature of:
20 °C

Additional information

Vapour pressure was determined at three different temperatures according to method A.4 EC 440/2008 (static method).

The apparatus which was used for vapour pressure measurements uses an electronic pressure gauge with a digital pressure indicator. The measuring range is from -50 kPa to 250 kPa with continuous measuring in this full range. The minimal resolution of the digital indicator is 0,1 kPa. The uncertainty of measurement is 1.5% of the reported value.

The measured vapour pressures were at:

20 deg.C= 0 kPa

35 deg.C=7.9 kPa

50 deg.C=19.4

The uncertainty of measurement was taken into account when using the value measured at 20 deg. C for the chemical safety assessment. Therefore, the value used as key value for safety assessment is: (measured value) + (resolution * uncertainty) = 0 + (0.1 kPa * 1.5%) = 0.0015 kPa.