Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 July 2011- 21 October 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
(2008)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Relative self-ignition temperature:
> 400 °C
Remarks on result:
other: No significant endothermic or exothermic effects

After the experiment, no test substance was left in the test cube or container that was placed below the cube.

Conclusions:
FDCA is not self-ignitable.

Description of key information

The substance is not self-ignitable. 

Key value for chemical safety assessment

Additional information

The test was performed in accordance with EC A.16. No self-ignition up to 400°C.