Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03-07-2017 – 03-07-2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Data from experimental study report

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: OECD 122
Principles of method if other than guideline:
A pH meter is essentially a voltmeter with high input impedance which measures the voltage of an electrode sensitive to the hydrogen ion concentration, relative to another electrode which exhibits a constant voltage
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
2-benzylideneheptanal
EC Number:
204-541-5
EC Name:
2-benzylideneheptanal
Cas Number:
122-40-7
Molecular formula:
C14H18O
IUPAC Name:
(2E)-2-(phenylmethylidene)heptanal
Test material form:
liquid
Details on test material:
Name of test material : (2E)-2-(phenylmethylidene)heptanalCommon name : 2-benzylideneheptanalMolecular formula : C14H18OMolecular weight : 202.2952 g/molPhysical appearence: LiquidSmiles notation : c1(\C=C(\CCCCC)C=O)ccccc1InChl : 1S/C14H18O/c1-2-3-5-10-14(12-15)11-13-8-6-4-7-9-13/h4,6-9,11-12H,2-3,5,10H2,1H3/b14-11-Substance type : Organic

Results and discussion

pH value
Key result
pH value:
4.53
Temp.:
26.8 °C
Concentration:
1 vol%
Remarks on result:
other: ACIDIC in nature

Applicant's summary and conclusion

Conclusions:
The pH determination of test item was done following OECD guideline 122. pH of 1% w/v emulsion was measured with the help of pH meter and it was observed to be 4.53 at 26.8 °C.
Executive summary:

The pH determination of test item was done as per the test guideline OECD 122. The mean pH of the test substance was determined with the help of digital pH meter. The mean pH was observed to be 4.53 at 26.8 °C.