Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 25, 2018 - September 27, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
effusion method: Knudsen cell
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
< 0 Pa
Remarks on result:
other: calculated
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
< 0 Pa
Remarks on result:
other: calculated
Test no.:
#1
Temp.:
50 °C
Vapour pressure:
< 0 Pa
Remarks on result:
other: calculated

The vapour pressure was measured in the temperature range of 45 °C to 120 °C. The measured vapour pressures at the corresponding temperatures are listed in Table 1. After the measurement no mass loss was determined.

Table 1: Measured vapour pressures and corresponding temperatures

 Temperature /°C  Vapour pressure / hPa

45

9.3E-6

50

2.8E-6

55

4.1E-6

65

6.7E-6

75

n.e

120

n.e

n.e.: not evaluable

The detection limit (1x10-5hPa) was used for the calculation as all measured vapour pressures were below the detection limit.

Table 2: Calculated vapour pressure at 20, 25 and 50 °C

 T / °C

 p /hPa

 p / Pa

20

<4.6E-10

<4.6E-8

25

<8.9E-10

<8.9E-8

50

<1.8E-8

<1.8E-6

This is a conservative estimation of the vapour pressure of the test item for the listed temperatures.

Conclusions:
The vapour pressure of the test item was below the detection limit of 1x10-7 Pa.
Executive summary:

A study was conducted according to OECD TG 104 and Regulation (EC) No 440/2008 method A.4 to determine the vapour pressure of the test item using the effusion method: Knudsen cell. The vapour pressure was measured in the temperature range of 45 °C to 120 °C. After the measurement no mass loss was determined. The vapour pressure of the test item was below the detection limit of 1x10-7 Pa. The vapour pressure of the test item was calculated to be <4.6E-8 Pa at 20 °C, <8.9E-8 Pa at 25 °C and <1.8E-6 Pa at 50 °C, respectively.

Description of key information

The vapour pressure of the test item was below the detection limit of 1x10-7 Pa.

The vapour pressure of the test item was estimated to be <4.6E-8 Pa at 20 °C, <8.9E-8 Pa at 25 °C and <1.8E-6 Pa at 50 °C, respectively.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

A study was conducted according to OECD TG 104 and Regulation (EC) No 440/2008 method A.4 to determine the vapour pressure of the test item using the effusion method: Knudsen cell (reference 4.6 -1). The vapour pressure was measured in the temperature range of 45 °C to 120 °C. After the measurement no mass loss was determined. The vapour pressure of the test item was below the detection limit of 1x10-7 Pa. The vapour pressure of the test item was estimated to be <4.6E-8 Pa at 20 °C, <8.9E-8 Pa at 25 °C and <1.8E-6 Pa at 50 °C, respectively.