Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 January 2009 to 12 March 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP in compliance with agreed protocols with no deviations from standard test guidelines and/or minor methodological deficiences which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
yes
Remarks:
the pile failed to ignite during the 2 minutes that the bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.
Principles of method if other than guideline:
Results of preliminary screening test obviated the need to perform the main test.
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): INK BH11 M
- Substance type: dark red powder
- Lot/batch No.: MB-1A
- Storage condition of test material: room temperature in the dark

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Material failed to ignite during the 2 minutes that a Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test
Executive summary:

In a determination of hazardous physico-chemical properties study (Harlan project number: 0959/0235) the test

material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test. The pile

failed to ignite during the 2 minutes that the Bunsen flame was applied. The result of the preliminary screening test

obviated the need to perform the main test.

The flammability (solids) was determined by measuring the burning rate of test material prepared as a pile of set

dimensions. Testing was conducted using Method A10 Flammability (Solids) of Council Regulation (EC) No 440/2008

of 30 May 2008, Part A: Methods for the determination of physico-chemical properties.