Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was conducted in conformance to GLP and on the basis of EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test), Cited as Directive 88/302/EEC, C.11
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Version / remarks:
Cited as Directive 88/302/EEC, C.11
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
no
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Laboratory culture:
- Pretreatment: Aeration, daily feed with synthetic medium; pH 7.6
Test type:
static
Water media type:
freshwater
Total exposure duration:
3 h
Remarks on exposure duration:
16.5 h was the stirring period of test item before the start of incubation
Test temperature:
20 +/- 2 °C (concerning the highest concentration of 10000 mg/l)
pH:
8.2 (concerning the highest concentration of 10000 mg/l)
Dissolved oxygen:
O2-start 5.1; O2-end 3.3 (concerning the highest concentration of 10000 mg/l)
Nominal and measured concentrations:
100, 1000 and 1000 mg/l
Details on test conditions:

TEST MEDIUM
Test concentration of the activated sludge: 480 mg/l suspended solids


OTHER TEST CONDITIONS
- Adjustment of pH: 8.2

EFFECT PARAMETERS MEASURED (with observation intervals if applicable) : respiration rate

TEST CONCENTRATIONS: 3 (100, 1000, 10000 mg/l)
Reference substance (positive control):
yes
Remarks:
3,5-Dichlorphenol (5, 10, 20 mg/l)
Duration:
3 h
Dose descriptor:
EC10
Effect conc.:
> 10 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate

Propylidynetrimethanol, propoxylated showed 2.7% respiration inhibition of activated sludge at a test item concentration of 10000 mg/l, hence the EC10 > 10000 mg/l.

Conclusions:
Propylidynetrimethanol, propoxylated showed 2.7% respiration inhibition of activated sludge at a test item concentration of 10000 mg/l, hence the E10 > 10000 mg/l.

Description of key information

3 hr (domestic sludge respiration rate inhibition) EC10 is >10'000 mgl/l . No inhibition of respiration was observed.

Key value for chemical safety assessment

Additional information

Toxicity to microorganisms has been tested with a sample of activated sludge from a domestic waste water treatment plant over a 3 hr period at nominal concentrations from 100 to 10'000 mgl/l. No effects were observed and the EC10 value is >10'000 mgl/l.