Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
yes
Remarks:
, see "Principles of method if other than guideline"
Principles of method if other than guideline:
The preliminary water solubility test indicated that the column elution method should have been performed as the solubility was less than 1x10e-2 g/L. However, due to the physical nature of the test material, it was not possible to use this method; experience has shown that liquid test materials coated onto glass beads cause these beads to adhere together forming a plug within the column and thus preventing water circulation.
Furthermore the results of the preliminary test indicated that the test material was essentially insoluble in water and that the loading rate had no influence on the final analysed TOC concentration. Therefore the definitive test was performed at a single loading rate only, that of 1.0 g/L.
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
481-740-5
EC Name:
-
Cas Number:
848301-67-7
Molecular formula:
main general molecular formula: CnH(2n+2)
IUPAC Name:
2,2,3,4,4,5,6-heptamethylheptane; 2,2,8-trimethyltetradecane; 2,2-dimethyldodecane; 2,2-dimethyltetradecane; 2-methyltetradecane; 3,5,7-triethyldecane; 4-ethyldodecane; 4-propyldodecane; 5,5-dipropylnonane; 5,7-dimethyl-4-propylundecane; 5-butyl-5-propyldecane; 5-butyl-5-propylnonane; 5-ethyl-5-propylnonane; 5-ethyl-7-methyl-4-propylundecane; 5-propyltridecane; 6-butyl-6-methyldodecane; 6-butyldodecane; 6-butylundecane; 7-methyl-4-propylundecane; 8-methyl-5-propyltridecane; 9-butyl-6-propylhexadecane; heptadecane; hexacosane; hexadecane; octane; pentadecane; tetradecane
Details on test material:
- Name of test material (as cited in study report): Distillates (Fischer-Tropsch), C8-26 branched and linear
- Substance type: Organic
- Physical state: Clear colorless liquid
- Analytical purity: 100%
- Impurities (identity and concentrations): Information not available
- Composition of test material, percentage of components: Information not available
- Isomers composition: Information not available
- Purity test date: Information not available
- Lot/batch No.: Information not available
- Expiration date of the lot/batch: Information not available
- Stability under test conditions: Stable under normal temperature and pressure
- Storage condition of test material: Room temperature, in the dark

Results and discussion

Water solubility
Water solubility:
< 1 other: mg TOC/L
Temp.:
20 °C
pH:
>= 5.1 - <= 5.3

Any other information on results incl. tables

1) Calculation

The total carbon content (TC) and inorganic carbon content (IC) of each sample were measured and calculated automatically by the TOC instrument from curves generated during calibration, The total organic carbon content (TOC) was then calculated by the instrument using the following equation: TOC = TC - IC

where:

TOC = total organic carbon (mg/L)

TC = total carbon content (mg/L)

IC = inorganic carbon content (mg/L)

2) Results

a) Preliminary test

The total organic carbon (TOC) content of the preliminary test samples are shown in the following table - each value has been corrected for a TOC result of 0.6 mg/L TOC determined for a water blank:

Sample Number Nominal Loading Rate (g/L) Mean TOC Content (mg/L)
1 0.10 1.8
2 1.00 <1.0
3 10.0 1.7

b) Definitive test

The TOC concentrations (mg/L) in the sample solutions are shown in the following table:

Solution Total Organic Carbon Content
 (TOC in mg/L)
Sample 1A 2.7
Sample 1B 2.7
Sample 2A 2.6
Sample 2B 2.7
Sample 3A 1.6
Sample 3B 1.6
Water blank 2.0

As the water blank represented a significant contribution towards each sample TOC content, it has been subtracted from the definitive test overall results. On subtracting the blank, the remaining TOC content for each sample was then below 1.0 mg/L (1.0 x l0^-3 g/L), the limit of quantification applied to the procedure. The results and sample treatment summary are shown in the following table:

Sample Number Time Shaken at ~30°C (hours) Time Equilibrated at 20°C (hours) TOC Content (g/L) Solution pH
1 24 24 <1.0 x 10-3 5.1
2 48 24 <1.0 x 10-3 5.2
3 72 24 <1.0 x 10-3 5.3

c) Overall result

Solubility less than 1.0 x 10-3 g TOC/L at 20.0 ± 0.5°C (arithmetic mean of three determinations).

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information): slightly soluble (0.1-100 mg/L)
water solubilty (at pH 5.1 - 5.3): less than 1 mg TOC/L at 20.0 ± 0.5°C [monitoring the total organic carbon (TOC) content of the sample solutions]
Executive summary:

The determination of the water solubility was carried out using the flask method, EU Method A.6, although the preliminary test indicated that the column elution method should have been performed as the solubility was less than 1x10e-2 g/L. However, due to the physical nature of the test material, it was not possible to use this method - experience has shown that liquid test materials coated onto glass beads cause these beads to adhere together forming a plug within the column and thus preventing water circulation.

Due to the test material being a complex mixture of hydrocarbons, and is also being essentially insoluble in water, analysis of the sample solution was performed monitoring the total organic carbon (TOC) content of the sample solutions only. The water solubilty was determined to be less than 1 mg TOC/L at 20.0 ± 0.5°C, monitoring the total organic carbon (TOC) content of the sample solutions (arithmetic mean of three determinations at pH 5.1 - 5.3).