Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09.08.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
described in the Council Regulation (EC) No 440/2008 of 30 May 2008
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
about 250 mm long

The test item was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end.Inthe preliminary screening test, the substance doesn’t ignite by a hot flame from a gas burner within 2 minutes. It only melts. Therefore the main test may be omitted.

 

According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 the test item 5424/18has not to be considered as flammable.

Description of key information

According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 the test item 5424/18 has not to be considered as flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test item was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end.Inthe preliminary screening test, the substance doesn’t ignite by a hot flame from a gas burner within 2 minutes. It only melts. Therefore the main test may be omitted.

 

According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 the test item 5424/18has not to be considered as flammable.