Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

General advice

- Show this safety data sheet to the doctor in attendance.

- First aider needs to protect himself.

- Place affected clothing in a sealed bag for subsequent decontamination.

In case of inhalation

- Move to fresh air.

In case of skin contact

- Take off contaminated clothing and shoes immediately.

- Wash off with soap and water.

- Consult a physician if necessary.

In case of eye contact

- Rinse with running water whilst keeping the eyes wide open (at least 15 minutes)

In case of ingestion

- Do NOT induce vomiting.

- Rinse mouth with water.

- If symptoms persist, call a physician.

Fire-fighting measures

Suitable extinguishing media

- powder

- Foam

- Aqueous film forming foam (AFFF).

- Sand

Unsuitable extinguishing media

- None known.

- Use extinguishing measures that are appropriate to local circumstances and the surrounding environment

Special hazards arising from the substance or mixture

- Harmful or toxic vapours are released.

- Combustible solid.

- Risk of dust explosion.

Special protective equipment for firefighters

- Full protective suit

- Self-contained breathing apparatus (EN 133)

Specific fire fighting methods

- Evacuate personnel to safe areas.

- Avoid release to the environment.

- Wear suitable protective equipment.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

- Do not breathe dust.

- Avoid contact with the skin and the eyes.

- Personal protective equipment

- Respiratory protection

- Wear suitable gloves.

- Safety glasses

- Signal word

- Mark the contaminated area with signs and prevent access to unauthorized personnel.

- Dam up.

- Should not be released into the environment.

Recovery

- Keep in properly labelled containers.

Disposal

- Treat recovered material as described in the section "Disposal considerations".

Handling and storage

Precautions for safe handling

- Provide adequate ventilation.

Technical measures/Storage conditions

- The floor of the depot should be impermeable and designed to form a water-tight basin.

- Stable under normal conditions.

- Keep away from incompatible materials to be indicated by the manufacturer

- Keep away from: Strong reducing agents., Strong oxidizing agents, Alkalis and caustic products., Acid chlorides and

anhydrides.

Packaging material

Suitable material

- Polyethylene

- drum

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not regulated
Shippingopen allclose all
Labels:
Not regulated
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not regulated
Shippingopen allclose all
Labels:
Not regulated
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not regulated
Shipping information
Proper shipping name and description:
Not regulated
Chemical name:
Not regulated
Labels:
Not regulated
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not regulated
Shipping information
Proper shipping name and description:
Not regulated
Chemical name:
Not regulated
Labels:
Not regulated
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering measures

- Effective exhaust ventilation system

Respiratory protection

- Use a respirator with an approved filter if a risk assessment indicates this is necessary.

- In the event of insufficient ventilation:

- Combined respiratory protective device, for filtering gas and particles, with an ABEK canister.

Hand protection

- PVC gloves

Eye protection

- Safety glasses with side-shields

Skin and body protection

- Full protective suit

Hygiene measures

- Handle in accordance with good industrial hygiene and safety practice.

Protective measures

- The protective equipment must be selected in accordance with current CEN standards and in cooperation with the

supplier of the protective equipment.

- Selection of appropriate personal protective equipment should be based on an evaluation of the performance

characteristics of the protective equipment relative to the task(s) to be performed, conditions present, duration of

use, and the potential hazards and/or risks that may occur during use.

- Handle in accordance with good industrial hygiene and safety practice.

Environmental exposure controls

- Dam up.

- Should not be released into the environmen

Stability and reactivity

Stable under normal conditions.

Incompatible materials

- Reacts with the following substances:

- Strong reducing agents.

- Strong oxidizing agents

- Acid chlorides

- Alkalis and caustic products.

Hazardous decomposition products

- On combustion forms:

- Toxic Gas

- Carbon oxides

Disposal considerations

Product Disposal

- Should not be released into the environment.

- Must be incinerated in a suitable incineration plant holding a permit delivered by the competent authorities.

Advice on cleaning and disposal of packaging

- Clean using hot water and a deodorizing agent.

- Following decontamination, re-use or recycle metal packaging.

- Dispose of in accordance with local regulations.

Measure for waste avoidance or recovery

- Do not dispose of with domestic refuse.

- Land-fill is forbidden.