Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
The boiling point could not be observed on a TA Instruments Q100 DCS using a standard heating profile. The decomposition point was measured on a TA instruments Q50 TGA. The experiment was started at 40 ºC, equilibrated for 5 min, and then the temperature was increased at 20 ºC/min to 650 ºC. The decomposition was observed as a nearly complete weight loss. The reported value of the decomposition point was determined using software supplied by TA Instruments.
GLP compliance:
not specified
Type of method:
differential thermal analysis
Remarks:
TGA

Test material

Results and discussion

Boiling point
Decomp. temp.:
> 306 °C

Any other information on results incl. tables

Decomposes before boiling

Applicant's summary and conclusion

Conclusions:
Decomposes before boiling
Executive summary:

Decomposes before boiling