Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 420-420-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Emergency measure - Inhalation: An die frische Luft bringen, ruhig lagern.
"ENGLISH"
Fresh air required, place in a resting position.
Emergency measure - Eyes: Mindestens 5 Minuten mit Wasser spülen.
"ENGLISH"
Rinse with water at least for 5 minutes.
Emergency measure - Skin: Mit Wasser und Seife abwaschen.
"ENGLISH"
Wash with water and soap.
Emergency measure - Ingestion: Ruhig lagern, warmhalten, Arzt hinzuziehen.
"ENGLISH"
Place in a resting position, keep warm, seek medical advice.
Fire-fighting measures
Recommended extinguishing agent: Schaum, Pulver, Kohlendioxid
"ENGLISH"
Foam, powder, CO2
Product arising from burning: Wasser, Kohlendioxid, Schwefeldioxid, Kohlenwasserstoffe
Wegen der Verunreinigung des Stoffes mit Dichlormethan
kann Phosgenbildung nicht ausgeschlossen werden.
"ENGLISH"
H2O, CO2, SO2, hydrocarbons. Formation of phosgene cannot be
excluded due to the impurity of dichloromethane.
Product determined by test: N
Protective equipment: Übliche Schutzausrüstung und Atemschutz.
Bei Phosgenbildung Gasfilter Typ B benutzen.
"ENGLISH"
Common fire and respiration protection.
If phosgene formates use gas filter type B.
Accidental release measures
Emergency measures in case of spillage: Eindringen in Erdreich, Gewässer und Kanalisation
verhindern. Mit flüssigkeitsbindendem Material aufnehmen.
Bei der Aufnahme des Stoffes sollte eine persönliche
Schutzausrüstung getragen werden (siehe unter Handhabung).
Die mit dem aufgenommenen Stoff gefüllten Behälter sind
ggf. unter Zuhilfenahme der TRGS 201 "Kennzeichnung von
Abfällen beim Umgang" ausreichend zu kennzeichnen.
"ENGLISH"
Avoid entering into the soil, the aquatic environment and
the sewage system. Take up with absorbing material. Wear
protective clothing during cleaning (see 2.3.10). Label
waste containers accordingly.
Handling and storage
Handling: Objektabsaugung, Schutzbrille und lösemittelbeständige
Schutzhandschuhe (Materialempfehlung: Nitril mit
Jerseyfutter) empfohlen.
Eine ausreichende Arbeitsplatzbelüftung ist sicherzustellen.
"ENGLISH"
Local ventilation, goggles and solvent resistant gloves
(nitril with jersey). Sufficient ventilation is necessary.
Storage: Beim Lagern in geschlossenen Gebinden bei Temperaturen bis
30°C sind keine gefährlichen Reaktionen bekannt. (Allerdings
darf das Produkt aus Qualitätsgründen nicht über 10°C
gelagert werden.)
Verwendung von festverschlossenen, bruchsicheren Behältern
bzw. von Originalbehältern. Behälter gegen Herabfallen
sichern, Produktreste auf/an den Behältern vermeiden.
"ENGLISH"
No dangerous reactions are known for storing at temperatures
< 30 °C. (Due to the quality of the substance it should be
stored at temperatures < 10 °C.)
Use tightly closed, unbreakable containers or original
containers. Safeguard containers against falling. Avoid
residues on/at containers.
Packaging of the substance and or preparation: Kannen aus Polyethylen, Weißblech oder Glasflaschen
(bruchsicher umverpackt).
Lagertemperatur zwischen 0° und 10°C.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport: Kein Gefahrgut im Sinne der Transportvorschriften.
Bruchsichere Behälter verwenden, Behälter gegen Herabfallen
sichern und ordnungsgemäß kennzeichnen.
"ENGLISH"
No hazardous transport good. Use unbreakable containers,
safeguard containers against falling and label accordingly.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Danger other than fire: Nicht bekannt
"ENGLISH"
Not known
Chemical reaction with water: Keine Reaktion
"ENGLISH"
No reaction
Dust explosion determined by test: N
Disposal considerations
Industry - Possibility of recovery/recycling: Keine Möglichkeiten
"ENGLISH"
No possiblities
Industry - Possibility of neutralisation: Nicht mehr einsetzbare Stoffreste der Sonderabfallentsorgung
über die HIM zuführen.
Ausgetretenes Produkt vorher mit flüssigkeitsbindendem
Material aufnehmen.
Code: 634
Neutralisierung durch spezielle Verfahren, z.B in einer An-
lage zur Entgiftung/Neutralisierung/Dehydratisierung/Sedi-
mentierung.
"ENGLISH"
Take up spoiled product with absorbant material. Give
residues to special disposal.
634:
Neutralisation by special techniques, e.g. in an
installation for detoxification/ neutralisation/
dehydration/ sedimentation
Industry - Possibility of destruction: controlled discharge: Eine Deponierung wird nicht empfohlen.
"ENGLISH"
Not recommended
Industry - Possibility of destruction - incineration: Kontrollierte Beseitigung über einen Sonderabfallentsorger.
In Verbrennungsanlage vernichten. Stoff enthält 15 % orga-
nisch gebundenen Schwefel.
Klassifizierung nach deutschem Recht: 55508 Anstrichmittel
Code: 661
Verbrennungsanlage mit Rauchgaswäsche
"ENGLISH"
Controlled disposal. The substance contains 15 % organic
bound sulfur.
661: Incinerator with flue gas scrubbing
Industry - Possibility of destruction - water purification: Die Produktionsabwässer werden nach Neutralisation mit
Natriumcarbonat in die am Standort befindliche
Abwasservorbehandlungsanlage (kombinierte chemische und
physikalische Anlage) gegeben.
"ENGLISH"
The waste waters are given into the local waste water pre-
treatment plant (combination chemical and physical) after
neutralisation with sodium carbonate.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.