Administrative data

Endpoint:
flammable solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 - 19 Dec 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D7094. Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 002602456
- Physical state: colorless, clear liquid
- Expiration date of the lot/batch: 07 June 2020

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature
- Stability under test conditions: test substance stable in water, but extremely volatile
Key result
Remarks on result:
other: no flash point up to 61 °C (test item boiled)

No flash-point was observed below 61 °C, the temperature at which the test item boiled.

Interpretation of results:
GHS criteria not met
Conclusions:
MTDID 22327 has no flash point up to 61 °C according to ASTM D7094.
Executive summary:

The flash point of MTDID 22327 was tested using a closed-cup method. Starting at 25 °C, an attempt was made to ignite the vapour of the test substance for every 2 °C temperature rise. No flash was observed below 61 °C, at which temperature the test item boiled. The study was conducted in accordance with ASTM D7094 and was GLP compliant; therefore the study is considered reliable without restrictions.

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 - 19 Dec 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 002602456
- Physical state: colorless, clear liquid
- Expiration date of the lot/batch: 07 June 2020

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature
- Stability under test conditions: test substance stable in water, but extremely volatile
Key result
Auto-ignition temperature:
> 650 °C
Atm. press.:
>= 1 022 - <= 1 033 hPa
Conclusions:
No auto-ignition of MTDID 22327 was registered up to 650 °C according to EU Method A.15.
Executive summary:

In a test of MTDID 22327, no auto-ignition was observed up to 650 °C. The study was conducted in accordance with EU Method A.15 and was GLP compliant; therefore the study is considered reliable without restrictions.