Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was done with an aqueous dispersion.
Cross-reference
Reason / purpose:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002. Remark: ASTM Method D93
GLP compliance:
yes
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Purity: not reported as such

Results and discussion

Any other information on results incl. tables

Flash point: None seen (evolving vapours extinguished the test flame).

Applicant's summary and conclusion

Conclusions:
None seen (evolving vapours extinguished the test flame).
Executive summary:

None seen (evolving vapours extinguished the test flame).