Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 946-239-2 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
skin: not irritating
eyes: not irritating
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Version / remarks:
- 28 July 2015
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
- Version / remarks:
- 6 July 2012
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 0011440677
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature
- Stability under test conditions: The stability under storage conditions over the study period was guaranteed by the sponsor, and the sponsor holds this
responsibility. - Test system:
- human skin model
- Remarks:
- EpiDermTM model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDermTM model EPI-200
- Tissue lot number(s): 23317
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37°C
- Temperature of post-treatment incubation: 37°C
REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: once with sterile PBS
- Observable damage in the tissue due to washing: no
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1.0 mg / mL MTT diluent
- Incubation time: 3 hours
- Spectrophotometer: SunriseTM Absorbance Reader
- Wavelength: 570 nm
- Filter: Measurement using a filter wavelength 570 nm without reference filter
FUNCTIONAL MODEL CONDITIONS WITH REFERENCE TO HISTORICAL DATA
- Viability: 1.567 ± 0.068
- Barrier function: 6.7 h
- Morphology: functional stratum corneum, viable cell layer, and intermediate spinous and granular layers
- Contamination: no
- Reproducibility: yes
NUMBER OF REPLICATE TISSUES: 3
CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
- killed tissues
- Procedure used to prepare the killed tissues: freezing
- N. of replicates : 2
PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 50%
- The test substance is considered to be non-corrosive to skin if the viability after 3 minutes exposure is greater than 50% and the viability after 1 hour exposure is greater than 20%.
Irritant potential of the test materials is predicted from the mean relative tissue viabilities compared to the negative control tissues concurrently treated with sterile PBS. A chemical is considered as "irritant", if the mean relative tissue viability with a test material is less than or equal to 50%. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- yes, concurrent MTT non-specific colour control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 30 µL
NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 30µL
POSITIVE CONTROL
- Amount(s) applied (volume or weight): 30µL
- Concentration (if solution): 5% (w/v) SDS in water - Duration of treatment / exposure:
- 1 hour
- Duration of post-treatment incubation (if applicable):
- 42 hours
- Number of replicates:
- 3
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 1 hour treatment (42-h postincubation)
- Value:
- 100.1
- Negative controls validity:
- valid
- Remarks:
- 100%
- Positive controls validity:
- valid
- Remarks:
- 3.4%
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- - OTHER EFFECTS:
- Visible damage on test system: no
- Direct-MTT reduction: no
- Colour interference with MTT: no
DEMONSTRATION OF TECHNICAL PROFICIENCY: yes
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes
- Acceptance criteria met for positive control: yes
- Acceptance criteria met for variability between replicate measurements: yes - Interpretation of results:
- GHS criteria not met
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- 28 July 2015
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 0011440677
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature
- Stability under test conditions: The stability under storage conditions over the study period was guaranteed by the sponsor, and the sponsor holds this responsibility. - Species:
- human
- Details on test animals or tissues and environmental conditions:
- - Description of the cell system used, incl. certificate of authenticity and the mycoplasma status of the cell live:
The EpiOcularTM model (OCL-200) is a three-dimensional non-keratinized tissue construct composed of normal human derived epidermal keratinocytes used to model the human corneal
epithelium . The EpiOcularTM tissues are cultured on cell culture inserts and are commercially available as kits containing 24 tissues on shipping agarose. The keratinocytes are tested free of bacteria, yeast, and other fungi. - Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 50 µL - Duration of treatment / exposure:
- 30 min
- Duration of post- treatment incubation (in vitro):
- 2 hours
- Number of animals or in vitro replicates:
- 2
- Details on study design:
- - RhCE tissue construct used, including batch number: EpiOcular™ OCL-200 kit (MatTek In Vitro Life Science Laboratories, Bratislava, Slovakia)
- Doses of test chemical and control substances used: 50 µL undiluted test substance, NC and PC
- Duration and temperature of exposure, post-exposure immersion and post-exposure incubation periods (where applicable): 30 min at 37°C, 2 hours post-incubation in medium
- Number of tissue replicates used per test chemical and controls (positive control, negative control, NSMTT, NSCliving and NSCkilled): 2
- Wavelength used for quantifying MTT formazan, and linearity range of measuring device: SunriseTM Absorbance Reader, for the determination of the optical density of colored extracts. Measurement using a filter wavelength 570 nm without reference filter.
- Description of the method used to quantify MTT formazan:
After the post-incubation period, the assay medium was replaced by 0.3 mL MTT solution and the tissues were incubated in the incubator for 3 hours.
After incubation, the tissues were washed with PBS to stop the MTT-incubation.
The formazan that was metabolically produced by the tissues was extracted by incubation of the tissues in isopropanol at room temperature overnight or for at least 2 hours.Blank values were established of 4 microtiter wells filled with isopropanol for each microtiter plate.
- Description of evaluation criteria used including the justification for the selection of the cut-off point for the prediction model
- Reference to historical positive and negative control results demonstrating suitable run acceptance criteria
- Reference to historical data of the RhCE tissue construct: yes
- Demonstration of proficiency in performing the test method before routine use by testing of the proficiency chemicals: yes
- Positive and negative control means and acceptance ranges based on historical data: yes
- Acceptance criteria for the NC:
The absolute OD570 of the NC-tissues in the MTT-test is an indicator of tissue viability obtained in the testing laboratory after the shipping and storing procedure and under specific conditions of the assay. Tissue viability is acceptable if the mean OD570 of the NC is >0.8. The mean OD570 of the NC should not exceed 2.5.
-Acceptance criteria for the PC:
Methyl acetate used as PC usually leads to a tissue viability of approx. 25%. A viability of < 50% is acceptable.
- Acceptance criteria for tissue variability:
Two tissues were treated under the same conditions. A variability between the two tissues is considered to be acceptable if the relative difference of the viability is < 20%
-Evaluation of results EPiOcular: The irritation potential of the test materials is predicted from the mean relative tissue viabilities compared to the negative control tissues concurrently treated with sterile water. A chemical is considered as "irritant", if the mean relative tissue viability with a test material is less than or equal to 60%. - Irritation parameter:
- other: % viability
- Run / experiment:
- 30 min exposure/2 h post-incubation
- Value:
- 89.1
- Negative controls validity:
- valid
- Remarks:
- 100%
- Positive controls validity:
- valid
- Remarks:
- 23.4%
- Remarks on result:
- no indication of irritation
- Interpretation of results:
- GHS criteria not met
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Skin
The potential of the test item to induce skin irritation was accessed in a GLP-conform in vitro study according OECD TG 439. The Skin irritation test was performed using the EpiDerm™ model, which consists of normal, human-derived epidermal keratinocytes. 30 µL of the undiluted test item was placed on the reconstructed three dimensional human epidermis model and incubated at 37°C for 1 hour, followed by a 42 -hour post-incubation peroid. As negative control (NC) sterile PBS was used and a dilution of 5% SDS in water was used as positive control (PC). The viability of the cells was measured using a colorimetic test (MTT-assay). The formazan production of the test-substance treated epidermal tissues is compared to that of negative control tissues. The quotient of the values indicates the relative tissue viability.
The test substance is not able to reduce MTT directly. The mean viability of the test-substance treated tissues determined after an exposure period of 1 hour with about 42 hours post-incubation was 100.1%. The PC-treated skin tissues showed a cell viability of 3.4%. Based on the observed results it was concluded, that the test item does not show a skin irritation potential in the EpiDerm™ in vitro skin irritation and corrosion test under the test conditions chosen (BASF SE, 69V0514/15A221; 2016).
Eye
The potential of the test item to induce eye irritation was assessed in a GLP-conform study according to OECD TG 492 (EpiOcular Eye Irritation Test). 50 µL of the test item was applied undiluted to a reconstructed three dimensional human cornea model (EpiOcular) and incubated for 30 min followed by a 2-hour post-incubation period. Tissue damage was measured using the colorimetric MTT assay. The formazan production of the test-substance treated epidermal tissues is compared to that of negative control tissues. The ratio of the values indicates the relative tissue viability. The test substance is not able to reduce MTT directly. The mean viability of the test-substance treated tissues was 89.1%.Based on the observed results for the EpiOcular Test alone it was concluded that the undiluted test substance does not show an eye irritation potential in the in vitro eye irritation test under the test conditions chosen (BASF SE 71V0514/15A222; 2016).
Justification for classification or non-classification
Classification, Labelling, and Packaging Regulation (EC) No 1272/2008
The available experimental test data is reliable and suitable for classification purposes under Regulation (EC) No 1272/2008. As a result the substance is not considered to be classified for skin or eye irritation under Regulation (EC) No 1272/2008, as amended for the tenth time in Regulation (EU) No 2017/776.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.