Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 209-683-1 | CAS number: 590-46-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Type of method:
- flask method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Type:
- log Pow
- Temp.:
- 20 °C
- pH:
- 1.9
- Remarks on result:
- not determinable because of methodological limitations
- Conclusions:
- The results show that no measurable transfer into the octanol phase took place. Therefore, it can be considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.
- Executive summary:
The results show that no measurable transfer into the octanol phase took place. Therefore, it can be considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.
- Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- accepted calculation method
- Justification for type of information:
- Calculation by EPI Suite KOWWIN v1.67 for CAS nr 590-46-5 (betaine hydrochloride, smiles CN(CL)(C)(C)CC(=O)(O) )
- Qualifier:
- no guideline required
- Principles of method if other than guideline:
- The partition coeffcient was predicted based on QSAR (KOWWIN v 1.67)
- GLP compliance:
- no
- Type of method:
- calculation method (fragments)
- Partition coefficient type:
- octanol-water
- Key result
- Type:
- log Pow
- Partition coefficient:
- -4.93
- Remarks on result:
- other: Log Pow predicted by QSAR (KOWWIN v1.67). Temperature and pH were not measured.
- Details on results:
- Log Kow(version 1.67 estimate): -4.93
SMILES : CN(CL)(C)(C)CC(=O)(O)
CHEM : (Carboxymethyl)trimethyl ammonium chloride
MOL FOR: C5 H12 CL1 N1 O2
MOL WT : 153.61
-------+-----+--------------------------------------------+---------+--------
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE
-------+-----+--------------------------------------------+---------+--------
Frag | 3 | -CH3 [aliphatic carbon] | 0.5473 | 1.6419
Frag | 1 | -CH2- [aliphatic carbon] | 0.4911 | 0.4911
Frag | 1 | -COOH [acid, aliphatic attach] |-0.6895 | -0.6895
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001
Const | | Equation Constant | | 0.2290
-------+-----+--------------------------------------------+---------+--------
Log Kow = -4.9274 - Conclusions:
- The estimated value for Log Kow for the test item is based on Kowwin (v1.67) calculations: -4.93
Referenceopen allclose all
The results show that no measurable transfer into the octanol phase took place. Therefore, it can de considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.
Description of key information
The results show that no measurable transfer into the octanol phase took place. Therefore, it can be considered that the measurement is not within the validity range of the OECD 107 or other methods to determine the log Pow. Due to this fact or further judgement or calculation, the calculated log Pow value of the test item should be used.
The estimated value for Log Kow for the test item is based on Kowwin (v1.67) calculations: -4.93
Key value for chemical safety assessment
- Log Kow (Log Pow):
- -4.93
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.