Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
Sponsor's identification p-diisopropylbenzene
Description Clear, colourless liquid
CAS number 100-18-5
Date received 31 August 2011
Expiry date Not supplied
Storage conditions Room temperature, in the dark
Temp.:
other: 25.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1.19
Conclusions:
The dynamic viscosity at 25 ⁰C was determined to be 1.19 +/- 0.20 mPa-s.
Executive summary:

The viscosity test was performed according to the caillary viscometer method. The dynamic viscosity at 25 °C was determined to be 1.19 +/- 0.20 mPa-s.

Description of key information

The viscosity test was performed according to the caillary viscometer method. The dynamic viscosity at 25 ⁰C was determined to be 1.19 +/- 0.20 mPa-s.

Key value for chemical safety assessment

Viscosity:
1.19 mPa · s (dynamic)
at the temperature of:
25 °C

Additional information