First-aid measures

Emergency measure - Eyes: Flush eyes with water for at least 15 mins, call a
physician.
Emergency measure - Skin: Wash exposed areas with water.
Emergency measure - Ingestion: Do not induce vomiting. Obtain medical attention. In all
cases, remove contaminated clothing.

Fire-fighting measures

Recommended extinguishing agent: Extinguishing media : water, chemical foam, carbon dioxide.
May emit oxides of nitrogen and cyanide fumes on
combustion. SCBA respiratory protection required for
fire-fighting personnel.

Accidental release measures

Emergency measures in case of spillage: Material is phytotoxic. Avoid contamination of water
supplies or outfall. Control and clean up as for any
non-reactive organic solid. If spill area is on ground near
trees or other valuable plants, remove top two inches of
soil and send to incineration.

Handling and storage

Handling: Protect eyes and skin. Use approved pesticide dust
respirator if the possibility exists of inhaling dust.
Handle only in well ventilated area.

Storage: Store in cool place. Keep container tightly closed. Keep
dry.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No hazard.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Decomposes slowly on exposure to water to give triazine and
sulphonamide. Polymerisation will not occur.

Disposal considerations

Industry - Possibility of recovery/recycling: Uncontaminated material may be reworked to meet product
specifications. Contaminated product must be destroyed (see
6.1.3).

Industry - Possibility of neutralisation: L5300 Technical may be neutralised by treatment with
caustic soda or commercial bleaching agent (sodium
hypochlorite solution) followed by conventional biological
treatment.

Industry - Possibility of destruction: controlled discharge: No.

Industry - Possibility of destruction - incineration: Dry product should be converted to an aqueous slurry before
incineration. Incineration should be carried out at 950 deg
C.

Industry - Possibility of destruction - water purification: In conjunction with preliminary neutralisation this is an
effective means of destruction.