Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: according to EC Directive 92/69/EEC and Regulation EC/440/2008 guideline methods under GLP conditions
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
equilibrium method closed cup
Flash point:
> 110 °C
Atm. press.:
1 015 hPa
Conclusions:
No flash point observed up to 110 degrees C by closed cup equilibrium method.
Executive summary:

No flash point observed up to 110 degrees C by closed cup equilibrium method.

Description of key information

Determined according to EC Directive 92/69/EEC Method 9A 
>110 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
110 °C

Additional information