Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to
Guideline:
other: MSZ EN ISO 3104:1996
GLP compliance:
not specified
Type of method:
other: Not reported
Key result
Temp.:
other: 100.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
174.3
Remarks on result:
other: Kinematic viscosity
Conclusions:
The kinematic viscosity of the substance as a 50% w.w. concentration in pharmaceutical white oil is 174.3 mm2/s at 100°C.
Executive summary:

The kinematic viscosity of the substance as a 50% w.w. concentration in pharmaceutical white oil is 174.3 mm2/s at 100°C. The kinematic viscosity was determined in a non-GLP-compliant guideline study (MOL-LUB 2013). The study is considered reliable and relevant for use for this endpoint.

Description of key information

The kinematic viscosity of the substance as a 50% w.w. concentration in pharmaceutical white oil is 174.3 mm2/s at 100°C.

Key value for chemical safety assessment

Viscosity:
174.3 mm²/s (static)
at the temperature of:
100 °C

Additional information

The kinematic viscosity of the substance as a 50% w.w. concentration in pharmaceutical white oil is 174.3 mm2/s at 100°C. The kinematic viscosity was determined in a non-GLP-compliant guideline study (MOL-LUB 2013).