Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2008-05-26 to 2008-12-16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reference:
Composition 1
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
1992
Deviations:
no
GLP compliance:
yes (incl. certificate)
Test material information:
Composition 1
Key result
Remarks on result:
no self-ignition observed up to the melting point

No self-ignition temperature was observed up to 72 °C (melting point was determined to be 71.5 °C).

Conclusions:
No self-ignition temperature of TODI was observed up to 72 °C (melting point was determined to be 71.5 °C).
Executive summary:

Using a linear heating rate of 0.5 °C/min, no self-ignition temperature of TODI was observed up to 72 °C (melting point was determined to be 71.5 °C).

Description of key information

No self-ignition temperature of TODI was observed up to 72 °C (melting point was determined to be 71.5 °C).

Key value for chemical safety assessment

Additional information

Using a linear heating rate of 0.5 °C/min, no self-ignition temperature of TODI was observed up to 72 °C (melting point was determined to be 71.5 °C).