Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 April 1991-25 November 1991
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1991
Report date:
1991

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl O-(4-amino-3,5-dichloro-6-fluoropyridin-2-yloxy)acetate
EC Number:
407-550-4
EC Name:
Methyl O-(4-amino-3,5-dichloro-6-fluoropyridin-2-yloxy)acetate
Cas Number:
69184-17-4
Molecular formula:
Hill formula: C8 H7 Cl2 F N2 O3 CAS formula: C8 H7 Cl2 F N2 O3
IUPAC Name:
methyl 2-[(4-amino-3,5-dichloro-6-fluoropyridin-2-yl)oxy]acetate
Details on test material:
- Name of test material (as cited in study report): Fluroxypyr methyl ester
- Physical state: white crystalline powder
- Analytical purity: 99.7% w/w
- Purity test date: 26.09.1990
- Lot/batch No.: AGR 279096
- Expiration date of the lot/batch: September 1992
- Storage condition of test material: below 5 °C

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
2.22
Temp.:
20 °C
Details on results:
Mean value of two determinations, 2.22 each. Equivalent Kow: 168.

Any other information on results incl. tables

Summary of HPLC/UV chromatographic data for determination of Kow of substance (pure):

Standard

or sample

Component

tR (s)

k

log k

log Kow

Standard

Run 3

(t0 = 84)

acetanilide

180

1.143

0.058

1

p-chloroaniline

236

1.810

0.258

1.83

nitrobenzene

292

2.476

0.394

1.9

anisole

388

3.619

0.559

2.1

ethyl benzoate

596

6.095

0.785

2.6

benzophenone

758

8.024

0.904

3.2

Sample 1

(t0 = 84)

substance

(pure)

378

3.500

0.544

2.22

Sample 2

(t0 = 88)

substance

(pure)

396

3.500

0.544

2.22

Standard

Run 4

(t0 = 86)

acetanilide

184

1.140

0.057

1

p-chloroaniline

240

1.791

0.253

1.83

nitrobenzene

298

2.465

0.392

1.9

anisole

396

3.605

0.557

2.1

ethyl benzoate

604

6.023

0.780

2.6

benzophenone

770

7.953

0.901

3.2

For better accuracy the mean calibration curve of Runs 3 and 4 was used for the bracketing reference injections.

The curve produced was:

log Kow = 2.263 log k + 0.993

where k denotes capacity factor: k = (tR-t0)/t0, tR - measured retention time, t0 - deadtime of I.D.S.

Applicant's summary and conclusion