Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: ISO 9001, non GLP
Qualifier:
equivalent or similar to guideline
Guideline:
other: DIN 51562 (1999-01)
GLP compliance:
no
Other quality assurance:
other: ISO 9001
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
>= 47.31 - <= 50.61

Measurement was preformed in waterfilled thermostatting bath with Schott capillaries (serial numbers descibed in the table above)

Conclusions:
The test material MeaTG 83 has been determined to have a kinematic viscosity of 48.96 ± 1.65 mm² / sec. @ 20°C (293.15 K).
The method were performed according to DIN 51562 (1999-01).

Description of key information

Measurement according to DIN 51562 UBBELODE, determination of kinematic (static)  viscosity.

Key value for chemical safety assessment

Viscosity:
48.96 mm²/s (static)
at the temperature of:
20 °C

Additional information