Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 22 - November 25, 1996
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study has been performed according to EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report date:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: Directive 92/69/EEC, A.9 "closed cup"
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): Nikkol VC-IP
- Substance type: Colourless to light yellow transparent liquid
- Physical state: Liquid
- Stability under test conditions: stable
- Storage condition of test material: In refrigerator in the dark

Results and discussion

Flash point
Flash point:
226.5 °C
Atm. press.:
99.7 - < 101.1 kPa

Applicant's summary and conclusion

Conclusions:
In conclusion, the flash-point of NIKKOL VC-IP is 226.5°C under the conditions of the test.