Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 March - 15 May, 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study has been performed according to OECD and/or EU guidelines and according to GLP principles.
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
non-equilibrium method closed cup
Key result
Flash point:
105 °C
Atm. press.:
101.3 kPa
Interpretation of results:
other: Not flammable according to CLP
Conclusions:
The flash-point of Ditetrahydrofurylpropane is 105°C (Pensky-Martens closed cup method).

Description of key information

Test performed according to EC A.9 (Pensky-Martens closed cup method)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
105 °C

Additional information