Registration Dossier

Environmental fate & pathways

Phototransformation in water

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

No removal from water by aeration for 4 hours, as determined by TOD analysis. Aeration test method, Environmental Research Lab., The Dow
Chemical Co.
If released into water, triethylene glycol monobutyl ether or (2-(2-(2-butoxyethoxy)ethoxy)ethanol) is not expected to adsorb to suspended solids and sediment based upon the estimated Koc. Volatilization from water surfaces is not expected to be an important fate process based upon this compound's estimated Henry's Law constant.

Key value for chemical safety assessment

Additional information

No removal from water by aeration for 4 hours, as determined by TOD analysis. Aeration test method, Environmental Research Lab., The DowChemical Co.

If released into water, triethylene glycol monobutyl ether or (2-(2-(2-butoxyethoxy)ethoxy)ethanol) is not expected to adsorb to suspended solids and sediment based upon the estimated Koc. Volatilization from water surfaces is not expected to be an important fate process based upon this compound's estimated Henry's Law constant.