Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Short-term toxicity to aquatic invertebrates

Administrative data

Endpoint:
short-term toxicity to aquatic invertebrates
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 1993
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study was done under GLP and is valid, however the analysis is questionable

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report date:
1993

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Method C2 of 84/449/EEC OECD Guideline 202
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
88% pure according to CoA

Sampling and analysis

Analytical monitoring:
yes

Test solutions

Vehicle:
no
Details on test solutions:
Identity and concentration of auxiliary solvent for dispersal: none

Test organisms

Test organisms (species):
Daphnia magna

Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
48 h

Test conditions

Hardness:
211 mg CaCO3/L
Test temperature:
17.5-19.5
pH:
7.6-8.4
Dissolved oxygen:
96-100% ASV
Nominal and measured concentrations:
nominal: 0, 0.75, 1.5, 3, 6, 12 mg/L
Reference substance (positive control):
no

Results and discussion

Effect concentrationsopen allclose all
Duration:
24 h
Dose descriptor:
EC50
Effect conc.:
2.69 mg/L
Duration:
48 h
Dose descriptor:
EC50
Effect conc.:
2.06 mg/L
Duration:
48 h
Dose descriptor:
NOEC
Effect conc.:
0.743 mg/L
Details on results:
%Concentration loss over test: 0 ... 99

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
Study is valid Ec50 was determined to be 2.06 mg/L