Registration Dossier

Administrative data

First-aid measures

If inhaled: move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact: Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician.
In case of eye contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed: Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Fire-fighting measures

Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Unsuitable extinguishing media: Water
Special hazards arising from the substance or mixture: Carbon oxides, Sulphur oxides, Hydrogen fluoride
Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Use personal protective equipment. Avoid breathing vapours, mist or gas. Ensure adequate ventilation.
Evacuate personnel to safe areas.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and cleaning up:
Soak up with inert absorbent material and dispose of as hazardous waste. Keep in suitable, closed containers for disposal.

Handling and storage

Precautions for safe handling:
Avoid contact with skin and eyes. Avoid inhalation of vapour or mist.
Conditions for safe storage, including any incompatibilities:
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Storage class (TRGS 510): Non-combustible, corrosive hazardous materials

Transport information

Land transport (ADR/RID)

UN number:
3265
Proper shipping name and description:
ADR/RID: CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S.
Chemical name:
Perfluorbutanesulfonic acid
Language:
English
Class:
8
Packaging group:
II
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
3265
Shippingopen allclose all
Class:
8
Packaging group:
II
Remarksopen allclose all

Marine transport (IMDG)

UN number:
3265
Proper shipping name and description:
IMDG: CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S.
Chemical name:
Perfluorbutanesulfonic acid
Class:
8
Packaging group:
II
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
3265
Proper shipping name and description:
IATA: Corrosive liquid, acidic, organic, n.o.s.
Chemical name:
Perfluorbutanesulfonic acid
Class:
8
Packaging group:
II
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Personal protective equipment
Eye/face protection
Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Full contact
Material: Fluorinated rubber
Minimum layer thickness: 0,7 mm
Break through time: 480 min
Material tested:Vitoject® (KCL 890 / Aldrich Z677698, Size M)
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0,4 mm
Break through time: 188 min
Material tested:Camatril® (KCL 730 / Aldrich Z677442, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374,
contact the supplier of the CE approved gloves. This recommendation is advisory only and must
be evaluated by an industrial hygienist and safety officer familiar with the specific situation of
anticipated use by our customers. It should not be construed as offering an approval for any
specific use scenario.
Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator
with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup
to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air
respirator. Use respirators and components tested and approved under appropriate government
standards such as NIOSH (US) or CEN (EU).
Control of environmental exposure
Do not let product enter drains.

Stability and reactivity

Reactivity: No data available
Stable under recommended storage conditions.
Possibility of hazardous reactions: No data available
Conditions to avoid: Exposure to moisture
Incompatible materials: Strong oxidizing agents, Strong bases, Water, Metals
Hazardous decomposition products: No data available

Disposal considerations

Dispose residues and and non-recyclable solutions to a licensed disposal company.
Contaminated packaging: Dispose of as unused product.