Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The result of the flashpoint of the test sample using the Pensky-Martens Closed Cup procedure was determined to be 'No Flash to Boiling' (NFTB) at 99.2 -99.3 kPa. Due to the sample boiling higher test temperatures above 119C could not be attained and therefore testing was terminated.

Key value for chemical safety assessment

Additional information

The auto-ignition temperature was determined in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A9