Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup
Flash point:
164 °C
Atm. press.:
ca. 1 013 Pa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of test substance was determined to be 164°C
Executive summary:

In this guideline (EU A.9) study conducted with GLP certification, the flash point of the test material (EC 213-426-9) was determined to be 164 ºC. The result of this study does not trigger classification as a flammable liquid under the criteria of the EU Classification, Labelling and Packaging (CLP) regulation (1272/2008).

Description of key information

Study carried out according to guideline and with GLP compliance.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
164 °C

Additional information

The substance is a solid with a relatively low melting point