Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

In accordance with Regulation (EC) No 440/2008 method A.16 Cyanuric chloride shows no auto-flammable properties.

Key value for chemical safety assessment

Additional information

A study according to Regulation (EC) No 440/2008 and according to VDI-Richtline 2263 was conducted. The Grewer oven test method was conducted, which is similar to the EU method A.16. and allows under the given circumstances the same conclusions. The Grewer Oven test can also serve as screening test for self-heating properties according the CLP Regulation. No self-ignition temperature was observed up to 433°C. Therefore the test item has not to be classified as self-heating substance in the sense of the classification criterla as laid down in Regulation (EC) No 1272/2006 (CLP). Also auto-flammability in the sense of the Regulation (EC) No 440/2008, method A.16. can be excluded.